Bosch Appliances 3.5 manual Connectors, Introduction, Connecting to the mains

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 169
Image 169
10.3 Connectors

Praesideo 3.5 Installation and User Instructions 4 Amplifiers

en 169

10.3 Connectors

10.3.1 Introduction

This section gives an overview of typical system connections with the multi channel interface and loudspeakers.

Connecting the mains (see section 10.3.2).

Connecting the multi channel interface (see section 10.3.3).

Connecting to ground (see section 10.3.4).

Connecting the amplifier channels (see section 10.3.5).

Connecting the local audio input (see section 10.3.6

Connecting the back-up power supply (see section 10.3.7)

10.3.2 Connecting to the mains

Proceed as follows to connect the basic amplifier to the mains:

1Select the correct local mains voltage using the voltage selector on the rear of the basic amplifier (see table 10.1).

table 10.1: Voltage selector and fuse

Selector

Mains voltage

Fuse

 

V(AC)

 

115

100 - 120

T6.3A H 250V

 

 

(IEC 60127 or UL 248)

230

220 - 240

T6.3A H 250V

 

 

(IEC 60127)

The mains supply can be supervised by the basic amplifier (see figure 10.2, no. 9) and is available for the multi channel interface.

10.3.3 Connecting to the multi channel interface

The connection to the multi channel interface (MCI) is made with two Ethernet connections. The MCI connections have a triangle and a circle symbol (see figure 10.5).

Caution

Do not connect the circle symbol connector of the multi channel interface to the triangle symbol connector of the power amplifier.

Caution

Always use CAT-5 modular plugs with an empty connector crimp part (refer to figure 10.4, part A). Some (pre-)assembled CAT-5 modular plugs have a connector crimp part that is filled with plastic (refer to figure 10.4, part B). These connectors do not give a reliable connection to the Ethernet connectors on the basic amplifiers and multi channel interfaces and can therefore can cause unexpected fault events.

2Put the correct type of fuse in the basic amplifier. The fuse is in the mains inlet. Note that the same

fuse value is used for both voltage ranges.

3 Connect the mains cord to the basic amplifier.

4Connect the mains cord to a locally approved mains outlet.

Mains

 

 

115/230V

115:

 

 

 

100-120V 50-60Hz

 

 

T10A 250V

 

 

230:

 

 

 

220-240V 50-60Hz

 

 

T6.3A H 250V

 

 

Signal Ground

 

 

Grounded

Floating

 

 

Supervision

 

 

Mains

+

0

Battery

On

 

 

 

 

 

B attery

48V

 

 

+

0

figure 10.3: Connecting mains power supply

AB

figure 10.4: (pre-) assembled CAT-5 modular plugs

Bosch Security Systems 2011-02

Page 169
Image 169
Bosch Appliances 3.5 manual Connectors, Introduction, Connecting to the mains, Connecting to the multi channel interface