Bosch Appliances 3.5 Incompatible hardware version, Invalid Firmware version, en, Group B fault

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 425
Image 425
Incompatible hardware version

Praesideo 3.5 Installation and User Instructions 10 Events

en 425

Event message:

Group B fault

Originator:

Output channel of multi channel interface, connected to a basic amplifier channel in which the fault occurred.

Extra information:

----

Description:

Logs the failure in group B for audio outputs with A/B switching or class-A wiring.

Resolve:

When the unit disconnects or when the fault is resolved manually.

Recommended action:

Check the loudspeaker connections on the Group B output of the basic amplifier channel.

Event message:

Incompatible hardware version

Originator:

Unit in which the fault occurred. Extra information:

The version number of the installed hardware and the lowest version number that is required to use the configured functionality.

Description:

Logs the mismatch of the version number of the unit hardware and the required hardware version number. The mismatch depends on the configured functionality of the unit. This fault event only occurs when the configured functionality cannot be handled by the hardware. Typically, this event occurs when multiple loudspeaker line supervision is used in combination with /00 Power Amplifiers.

Resolve:

When the unit disconnects.

Recommended action:

Use a newer version of the unit that caused the fault OR

Downgrade to a lower software version

Event message:

Invalid Firmware version

Originator:

Unit that has an invalid firmware version. Extra information:

Current firmware version number of the unit and the minimal required version number of the firmware. Description:

Logs the mismatch of the firmware version number of the unit and the minimal required firmware version number.

Resolve:

When the unit is upgraded. Recommended action:

Update firmware. This action is available in the configuration web pages.

Event message:

Keypad mismatch

Originator:

Call station in which the fault occurred.

Extra information:

KP: keypad, NKP: numeric keypad.

Description:

Logs the mismatch of the number of configured and detected (numeric) keypads.

Resolve:

When the fault disappears or when the call station disconnects.

Recommended action:

Make sure that the number of configured (numeric) keypads is equal to the number of (numeric) keypads that are connected to the call station.

Bosch Security Systems 2011-02

Page 425
Image 425
Bosch Appliances 3.5 manual Incompatible hardware version, Invalid Firmware version, en, Group B fault, Keypad mismatch