Praesideo 3.5 Installation and User Instructions 8 Software

en 312

36.2.2 Praesideo core software

The Praesideo core software consists of the File Transfer Application and all files that must be transferred to the network controller and other units in the system.

Proceed as follows:

1Start the PRS-SW Praesideo Software DVD (see section 35.2). A screen similar to the one in figure 35.1 appears.

2Go to Mandatory > Praesideo core x.yy.zzzz (where x.yy is software release number and zzzz is the build number). A File Download window appears.

3Click the Run button to start the Praesideo core software setup program.

4Follow the instructions that are displayed on screen. A notification is displayed when the installation is finished.

36.2.3 SVG viewer

The SVG viewer must be installed on the configuration PC to be able to operate the audio processing part of the web interface. Proceed as follows:

1Start the PRS-SW Praesideo Software DVD (see section 35.2). A screen similar to the one in figure

35.1 appears.

2Go to Mandatory > SVG viewer. A File Download window appears.

3Click the Open button to start the SVG viewer setup program. Follow the instructions that are displayed on screen. A notification is displayed when the installation is finished.

36.3Establishing connection

After the mandatory software has been installed on the configuration PC (see section 36.2), the configuration PC must establish a connection with the network controller to be able to transfer the system files to the network controller and other units in the system (see section 36.4). Proceed as follows:

1If the network controller is connected to an existing Ethernet, ask the network administrator for:

An IP address for the network controller.

A suitable subnet mask.

The IP address of the default gateway for the

network controller.

2Go to screen 2Ba of the menu display of the network controller to set the IP address of the network

controller. See section 5.5 for the configuration menu.

3 Go to screen 2Bb of the menu display of the network controller to set the subnet mask of the network controller.

4 Go to screen 2Bc of the menu display of the network controller to set the default gateway for the network controller.

5 Connect the network controller to an existing Ethernet network or directly to the configuration PC.

6On the configuration PC, go to Start > Run and enter cmd to open a command prompt window.

7Ping the network controller. For example, if the IP address of the network controller is 192.168.0.15, enter ping 192.168.0.15.

If no connection is possible, a screen similar to the one in figure 36.2 appears.

If a connection can be established, a screen similar to the one in figure 36.3 appears.

Microsoft Windows 2000 [Version 5.00.2195]

(C)Copyright 1985-2000 Microsoft Corp. C:\>ping 192.168.0.15

Pinging 192.168.0.15 with 32 bytes of data:

Request timed out

Request timed out

Request timed out

Request timed out

Ping statistics for 192.168.0.15:

Packets: Sent = 4, Received = 0, Loss = 4 (100% loss)

Approximate round trip in milli-seconds:

Minimum = 0 ms, Maximum = 0 ms, Average = 0 ms

figure 36.2: Incorrect communication

Bosch Security Systems 2011-02

Page 312
Image 312
Bosch Appliances 3.5 manual Establishing connection, Praesideo core software, SVG viewer

3.5 specifications

Bosch Appliances has established itself as a leader in home technology, known for its commitment to quality, innovation, and sustainability. The Bosch 3.5 series epitomizes this ethos, offering a range of appliances designed to enhance everyday living while ensuring energy efficiency and ease of use.

At the heart of the Bosch 3.5 line is the integration of advanced technologies optimized for performance. One standout feature is the EcoSilence Drive, a brushless motor used in dishwashers and washing machines. This technology ensures quieter operation while offering reliability and energy savings. Customers can appreciate a peaceful home environment while benefiting from powerful cleaning options.

Another significant characteristic of Bosch appliances is their focus on precision and customization. The Bosch 3.5 series includes models with adjustable shelving and customizable interior layouts, allowing consumers to maximize storage according to their needs. The flexibility in functionality is complemented by features such as the VarioFlex and VarioDrawer systems in dishwashers, which offer additional loading options for better convenience.

Zones such as cooking and refrigeration have also seen remarkable improvements in the 3.5 series. The induction cooktops utilize speed and precision to deliver quick cooking experiences while maintaining safety, thanks to features like automatic shut-off and child lock. Furthermore, Bosch refrigerators included in this line employ innovative cooling technologies, such as the Dual Compressor system, which ensures optimal freshness for longer by preventing odor transfer between compartments.

Sustainability is a key characteristic of Bosch products. The 3.5 series appliances are designed to meet stringent energy efficiency standards, with many models Energy Star certified. This commitment to environmental stewardship resonates with eco-conscious consumers who seek to reduce their carbon footprint without sacrificing performance or style.

Aesthetically, Bosch appliances in the 3.5 line boast sleek designs that harmonize with modern kitchen aesthetics. With stainless steel finishes, multi-functional interfaces, and intuitive controls, these appliances not only perform exceptionally but also contribute to a sophisticated home environment.

In conclusion, Bosch Appliances 3.5 series integrates cutting-edge technology, sustainable practices, and user-centric designs, making them an optimal choice for modern households looking for reliability, efficiency, and style. Whether for cooking, cleaning, or preservation, Bosch continues to set the standard in home appliances.