Praesideo 3.5 Installation and User Instructions EN60849: 1998

en 20

EN60849 - 5.4 Monitoring of software controlled equipment

Requirement

Compliance

Signature

The correct execution of the system software by any

 

 

microprocessor shall be monitored by internal self-

 

 

checking procedures and by an appropriate monitoring

 

 

circuit (e.g. "watch dog" circuit) complying with the

 

 

following:

 

 

a The monitoring circuit and its associated indication

Compliant.

 

and signalling circuits shall not be prevented from

 

 

determining and signalling a fault condition by the

 

 

failure of any microprocessor or associated clock

 

 

circuits.

 

 

b The monitoring circuit shall monitor the execution of

Compliant. Indication on Call Station Basic and Call

 

routines associated with the main program

Station Kit if properly installed.

 

elements (i.e. it shall not be solely associated with

 

 

"waiting" or other "housekeeping" routines).

 

 

c In the event of a failure by a microprocessor to

Compliant. Fault are indicated by a control output of the

 

execute its software correctly, the monitoring circuit

Network Controller, if properly installed. Responsibility

 

shall (in addition to initiating an audible and visual

of the installer.

 

fault warning) perform as follows:

 

 

1 re-initialize the processor and attempt to restart

Compliant, both data and program are checked for the

 

the program at a suitable point within 10 s of

Network Controller and the firmware in the units.

 

the occurrence of the failure. The re-

 

 

initialisation procedure shall verify that the

 

 

contents of memory, both program and data,

 

 

are not corrupted, and

 

 

2 either

 

 

i record that a failure has occurred (using a

Compliant.

 

system capable of recording a minimum of

 

 

99 failures and re-settable only by an

 

 

operation restricted to authorized servicing

 

 

personnel) or

 

 

ii automatically reset the equipment and give

 

 

an audible and visual warning that an

 

 

automatic reset has occurred.

 

 

EN60849 - 5.5 Interface with emergency detection system

 

 

 

 

Requirement

Compliance

Signature

The communication link between the emergency

Compliant, if properly installed using supervised control

 

detection system and the sound system shall be

inputs. Responsibility of the installer.

 

continuously monitored for faults. This is normally

 

 

performed by the control equipment for the emergency

 

 

detection system, which gives an audible and visual

 

 

indication of a fault in the link between the two systems.

 

 

The emergency detection system shall also be capable

Compliant, if properly installed using control outputs.

 

of receiving information regarding faults in the sound

Responsibility of the installer.

 

system and shall include a provision, usually at its

 

 

control and indicating equipment, for appropriate

 

 

audible and visual indication of such faults. As a

 

 

minimum, the sound system shall be capable of

 

 

transmitting to the emergency detection system one

 

 

general "Sound system fault" for any of the fault

 

 

conditions listed in 5.3 that may occur within the sound

 

 

system.

 

 

The link between a fire detection and alarm system and

Compliant, if properly installed. Responsibility of the

 

the voice alarm system is of crucial importance in

installer. Control input should be in toggle mode.

 

maintaining the integrity of overall operation. It may be

 

 

desirable on larger systems, where distributed control equipment is used, to provide a link at each control equipment location rather than to rely on a central location. Each link shall be monitored. The voice alarm system shall be capable of continuing to broadcast alarm messages, which have been initiated by the fire detection and alarm system, even in the event of a subsequent fault in the interconnecting link between the two systems (i.e. the voice alarm system shall "latch" on receipt of a signal from the fire detection and alarm system). Interruption by higher priority broadcasts shall still be possible.

Bosch Security Systems 2011-02