43.4.3 General (LBB4433/00)

Praesideo 3.5 Installation and User Instructions 9 System Configuration

en 354

43.4.3 General (LBB4433/00)

figure 43.23: Configure call station, step 3

table 43.11: General configuration settings (LBB4433/00)

Item

Value

Description

Class

Normal

Sets the priority range of the call station. This is either Normal

 

Emergency

for 32 to 223 or Emergency for 32 to 255. When Class is

 

 

Emergency the call station can make fail-safe calls.

Clear selection after call

Yes

Selects whether selections that are made on a keypad for a call

 

No

(zone selection, priority selection, tone selection and message

 

 

selection) will be cleared after the call has finished or will be

 

 

kept for a next call.

Network power

On

When Network power supervision is On and the network

supervision

Off

power is failing, a fault event is generated.

Back-up power

On

When Back-up power supervision is On and the back-up

supervision

Off

power is failing, a fault event is generated.