Praesideo 3.5 Installation and User Instructions 10 Events

en 432

Event message:

SCB failure / Supervision Control Board failure Originator:

The multi channel interface or the power amplifier output in which the fault occurred.

Extra information:

----

Description:

Logs the failure of a supervision control board, that is part of a multi channel interface or that is mounted in a power amplifier.

Resolve:

When the fault is no longer present and the unit has been switched off and on again.

Recommended action:

Replace the failing supervision control board of the power amplifier channel or replace the multi channel interface.

Event message:

Unit missing

Originator:

Unit that is missing Extra information:

The network controller detects missing units within 1 minute and missing Open Interface clients within 10 minutes.

Description:

Logs the absence of a configured unit. Resolve:

When the unit reconnects. Recommended action:

Disable the configured unit with the configuration software or connect the missing unit to the system.

Event message:

Unit not configured

Originator:

Unit that is not configured. Extra information:

This fault event cannot be generated by open interface clients.

Description:

Logs the connection of a unit that is not configured. Resolve:

When the unit disconnects. Recommended action:

Check the serial number and type of the unit that generated the event. Use the configuration software to configure and enable the unit.

Event message:

Unknown unit type

Originator:

Unit that was not recognized by the network controller.

Extra information:

This fault event cannot be generated by open interface clients.

Description:

Logs the connection of a unit of an unknown type. Resolve:

When the unit disconnects.

Recommended action:

If the unit is not needed, disconnect it from the system. If the unit is needed, upgrade to a software version that supports the unit type. If the current software version supports the unit type, the unit is broken and must be repaired.