42.3Network controller

Praesideo 3.5 Installation and User Instructions 9 System Configuration

en 332

The hexadecimal serial number of a unit consists of 8 digits ranging from 0 to F. The combination of the first and second digit identifies the type of unit.

table 42.1: Serial number ranges (addressable units)

Type no.

Description

ID

PRS-NCO-B

Network Controller

11

PRS-16MCI

Multi Channel Interface

1B

LBB4402/00

Audio Expander

12

LBB4404/00

CobraNet Interface

1C

PRS-NSP

Network Splitter

14

 

 

 

PRS-FIN(S)

Fiber Interface

15

PRS-FINNA

 

 

PRS-1P500

Power Amp. 1 x 500 W

0B

PRS-2P250

Power Amp. 2 x 250 W

0A

PRS-4P125

Power Amp. 4 x 125 W

09

LBB4428/00

Power Amp. 8 x 60 W

08

 

 

 

LBB4430/00

Call Station Basic

0C

LBB4433/00

Call Station Kit

0E

PRS-CSI

Remote Call Station

1D

 

(Call Station Interface)

 

PRS-CRF

Call Stacker

1F

42.3Network controller

Proceed as follows to register the network controller:

1Go to Configure > System definition > Network controller. A screen similar to the one in figure 42.3 appears in the main frame of the web interface.

figure 42.3: Register network controller, step 1

2Enter a name for the network controller in the Name field.

Note

The name is also shown on the display of the network controller.

Note

If the real serial number is not (yet) known, the temporary serial number 0 can be used for all units. In this way, most of the configuration can be done off-line already. Communication with actual units in the system is only possible when the temporary serial numbers have been replaced by the real serial numbers. Units in the configuration with the serial number 0 are ignored by the actual system in operation.

3Enter the hexadecimal serial number of the network controller in the Serial number field.

4When the network controller is physically present, it can be enabled by ticking the Enabled checkbox.

Note

The serial number itself is not checked. However, the software checks that all entered characters are hexadecimal characters and that the serial number is 8 characters long or is 0.

5Submit the changes. Note that the changes are not permanent until the configuration is saved. (see section 40.4.4 and section 40.4.5).