Bosch Appliances 3.5 manual 8: Press-to-talkPTT key, 10: Externally powered relay, en

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 222
Image 222
figure 18.8: Press-to-talk (PTT) key

2011-02 Installation and User Instructions 5 Call Stations

en 222

It is possible to connect the following to the control inputs/outputs connector:

Press-to-talk (PTT) key. See figure 18.8 for a connection diagram. The two resistors must be placed in the circuit, because the contact is always supervised by the system software.

Internally powered lamp or LED. See figure 18.9 for a connection diagram.

Externally powered lamp or LED. See figure 18.9 for a connection diagram.

Externally powered relay. See figure 18.11 for a connection diagram.

10 kΩ

PTT Input

10 kΩ

Contact

5V

 

 

 

 

10 kΩ

 

GND

 

figure 18.8: Press-to-talk (PTT) key

I < 100 mA

Max. 56V

Output X, IN

GND

figure 18.10: Externally powered relay

I < 100 mA

Max. 56V

Output X, IN

GND

figure 18.11: Externally powered relay

 

+5V, 30 mA

 

 

 

 

 

 

R2

R2

R2

7

R2

R2

 

3

 

5

9

11

 

R1

 

R1

R1

R1

R1

 

PI

 

FI

CI

SPI

SEI

 

4

 

6

8

10

12

 

62V

62V

62V

 

62V

62V

PI

= Power Indicator

 

R1 = 0 Ω, R2 = 330 Ω (HW07/04 and later)

 

FI

= Fault Indicator

 

R1 = 180 Ω, R2 = 150 Ω (HW07/00 to HW07/03)

CI

= Call Indicator

 

R1 = 330 Ω, R2 = 0 Ω (before HW07/00)

 

SPI = System Priority Indicator

 

 

 

 

SEI = System Emergency Indicator

 

 

 

 

figure 18.9: Internally powered LED

Bosch Security Systems 2011-02

Page 222
Image 222
Bosch Appliances 3.5 manual 8: Press-to-talkPTT key, 10: Externally powered relay, 11: Externally powered relay, en