Praesideo 3.5 Installation and User Instructions EN54-16: 2008

en 29

Clause / Requirement

5.3 Indication on alphanumeric displays

Where an alphanumeric display is used to display indications relating to different functional conditions these may be displayed at the same time. However, for each functional condition there shall be only one window, in which all of the information relating to that functional condition is grouped.

5.4 Indication of the supply of power

5.4.1A visible indication shall be given by means of a separate discrete light-emitting indicator while the VACIE is supplied with power.

5.4.2Where the VACIE is distributed in more than one cabinet, an indication of supply of power to each distributed cabinet shall be given at that point.

5.5 Additional indications

Where additional indications are provided, they shall be clearly identifiable and shall not override the primary indication of the VACIE.

Compliance

Signature

Praesideo is compliant.

The alphanumeric display of the network controller indicates the voice alarm condition by means of the emergency menu. The display indicates the fault warning condition by means of the faults menu.

If a fault occurs in the system, the faults menu is displayed automatically. If the system enters the voice alarm condition, the emergency menu is displayed automatically. The emergency menu has precedence over the faults menu.

The faults menu has a submenu for each individual fault. The user can scroll through the individual faults.

The logging application delivered with the Praesideo system offers a graphical user interface for viewing events (Logging Viewer). The Logging Viewer has three separate tab pages: Fault Events (shows events related to the fault warning condition), Call Events and General Events (shows events related to the voice alarm condition).

Praesideo is compliant.

Each Praesideo system component either has a dedicated power LED or a display with a backlight. For components with a power LED, the LED is on when the component is supplied with power. For components with a display, the backlight of the display is on when the component is supplied with power.

The Praesideo system can be distributed in more than one cabinet, depending on the installation of the system. Many system components can be mounted in a 19’’ rack. Each cabinet will indicate supply of power independently if the system is distributed in more than one cabinet.

Praesideo is compliant.

For LEDs with multiple indication functions , all of the additional indications are clearly identified (in the Installation and User Instructions of the Praesideo system); since the fault warning indication and the voice alarm indication always have precedence over the additional indications, the primary indications are not overridden.

The LED indicator belonging to a key of the call station keypad is used for status indications. The status indications depend on the function which has been assigned to the programmable key. The Installation and User Instructions of the Praesideo system clearly identifies the possible status indications. These status indications do not override the primary indication of the Praesideo system, since they are separate LEDs.

The display of the network controller offers a menu that is also used for other indications than indication of the voice alarm and/or fault warning condition. The Installation and User Instructions of the Praesideo system clearly identifies the other indications of the menu. The other menus do not override the emergency and faults menu; indication of the faults menu and emergency menu has precedence (higher priority) over indication of the other menus.

Bosch Security Systems 2011-02

Page 29
Image 29