• Press-to-talk (PTT) key. See figure 21.8 for a

2011-02 Installation and User Instructions 5 Call Stations

en 246

It is possible to connect the following to the control inputs/outputs connector:

Press-to-talk (PTT) key. See figure 21.8 for a

connection diagram. The two resistors must be

placed in the circuit, because the contact is always

supervised by the system software.

• Internally powered lamp or LED. See figure 21.9 for

a connection diagram.

• Externally powered lamp or LED. See figure 21.10

for a connection diagram.

• Externally powered relay. See figure 21.11 for a

Output X, IN

GND

I < 100 mA

R

Max. 56V

connection diagram.

10 kΩ

PTT Input

10 kΩ

Contact

5V

 

 

 

 

10 kΩ

 

GND

 

figure 21.8: Press-to-talk (PTT) key

figure 21.10: Externally powered LED

I < 100 mA

Max. 56V

Output X, IN

GND

figure 21.11: Externally powered relay

 

+5V, 30 mA

 

 

 

 

 

 

R

R

 

R

R

R

 

3

5

 

7

9

11

 

PI

 

FI

CI

SPI

SEI

 

4

6

 

8

10

12

 

62V

62V

 

62V

62V

62V

PI

= Power Indicator

 

 

R = 330 Ω

 

 

FI

= Fault Indicator

 

 

 

 

 

CI

= Call Indicator

 

 

 

 

 

SPI = System Priority Indicator

 

 

 

 

SEI = System Emergency Indicator

 

 

 

 

figure 21.9: Externally powered LED

Bosch Security Systems 2011-02