25.3Connections

Praesideo 3.5 Installation and User Instructions 6 Installation Accessories

en 266

25.3Connections

25.3.1 Introduction

This section gives an overview of typical system connections using the network splitter:

Looping through the main branch (see section 25.3.2).

Creating tap-offs (see section 25.3.2).

Connecting an external power supply (see section 25.3.3).

25.3.2Connecting the main branch and creating tap-offs

See figure 25.5 for information about connecting the main network and the tap-offs to the network splitter.

tap-off 1

main branch

23

78

tap-off 2

main branch

figure 25.5: Connecting the network splitter

25.3.3 Connecting a power supply

This unit is powered by the network controller, via the Praesideo system bus. But the network splitter is delivered with a separate Kycon KPP4-P connector to connect an external power supply to the network splitter.

Note

The external power supply can only feed the tap-offs and not the main network branch. Whether it really does depends on the jumper settings inside the network splitter.

The Kycon KPP-4P connector has four pins (see figure 25.6):

1 3

2 4

figure 25.6: Connection diagram (external view)

table 25.1: Kycon KPP-4P connector details

Pin Signal

1Ground

2Power from external power supply to the PRS-NSP (max. 48 V / 5 A)

3Output power from the system bus (max. 48V / 2 A)

4Not connected