Epson Research and Development Page 11
Vancouver Design Center
13504DCFG Configuration Program S1D13504
Issue Date: 01/02/01 X19A-B-008-02
Clocks Tab
Figure 3: Clocks Tab
The Clocks Tab allows manual selection of either the clocks or the required timings. From
this information 13504DCFG calculates the required timings (if c locks are specif ied) or the
required clocks (if timings are specified). The program calculates the clocks automaticall y
when the Auto setting is checked.
If clock selections are manually changed, it may modify or invalidate CRT or panel timings
selected previously. Changing the settings on the Clocks Tab alters th e settings on the Panel
and CRT Tabs. Confirm all settings on these two tabs after manually changing any clock
settings.
Note
If the same source clock is selected for use by both CRT and LCD panels, the available
LCD pixel clock selections are limited due to the more stringent CRT timings.