Comments
The PC must not have more than 12M bytes of system memory when used with the
S5U13504B00C board.
Follow simultaneous display guidelines for correct simultaneous display operation.
To determine if the CRT will operate correctly when using a dual panel, refer to the Maximum
Frame Rates table in the S1D13504 Functional Hardware Specification, document number
X19A-A-002-xx.
When editing in 13504CFG with CRT enabled and panel disabled, select Single Panel from the
Edit Panel Setup submenu.
When a CRT is enabled, the CRT settings will override the panel settings. If a panel is also used,
the CRT timing values will have to be changed to more closely match the panel's timing.
A CRT cannot show 15 or 16 bits-per-pixel.
Do not attach a panel with a 16-bit interface to the S1D13504 when a CRT is also attached.
Program Messages
ERROR: Too many devices registered.
There are too many display devices attached to the HAL. The HAL can only manage 10 devices
simultaneously.
ERROR: Could not register S1D13504 device.
A 13504 device was not found at the configured addresses. Check the configuration address using
the 13504CFG configuration program.
ERROR: Did not detect S1D13504.
The HAL was unable to read the revision code register on the S1D13504. Ensure that the S1D135 04
hardware is installed and that the hardware platform has been set up correctly.