Page 6

Epson Research and Development

 

Vancouver Design Center

 

 

Comments

All numeric values are considered to be hexadecimal unless identified otherwise. For example, 10 = 10h = 16 decimal; 10t = 10 decimal; 010b = 2 decimal.

Redirecting commands from a script file (PC platform) allows those commands to be executed as though they were typed.

The PC must not have more than 12M bytes of memory when used with the S5U13504B00C board.

Follow simultaneous display guidelines for correct simultaneous display operation.

To determine if the CRT will operate correctly when using a dual panel, refer to the “Maximum Frame Rates” table in the S1D13504 “Functional Hardware Specification,” document number X19A-A-002-xx.

When editing in 13504CFG with CRT enabled and panel disabled, select “Single Panel” from the “Edit Panel Setup” submenu.

When a CRT is enabled, the CRT settings will override the panel settings. If a panel is also used, the CRT timing values will have to be changed to more closely match the panel's timing.

A CRT cannot show 15 or 16 bits-per-pixel.

Do not attach a panel with a 16-bit interface to the S1D13504 when a CRT is also attached.

Program Messages

ERROR: Too many devices registered.

There are too many display devices attached to the HAL. The HAL can only manage 10 devices simultaneously.

ERROR: Could not register S1D13504 device.

A 13504 device was not found at the configured addresses. Check the configuration address using the 13504CFG configuration program.

S1D13504

13504PLAY Diagnostic Utility

X19A-B-005-05

Issue Date: 01/02/01

Page 254
Image 254
Epson S1D13504 manual Comments