Epson Research and Development

Page 5

Vancouver Design Center

 

 

 

The file mode0.h contains the register values required to set the screen resolution, col- or depth (bpp), display type, active display (LCD/CRT), rotation, etc. The mode0.h file included with the drivers, may not contain applicable values and must be regener- ated. The configuration program 13504DCFG can be used to build a new mode0.h file. If building for 8 bpp, place the new mode0.h file in the directory “x:\13504\8bpp\File”. If building for 16 bpp, place the new mode0.h file in “x:\13504\16bpp\File”.

Note

Mode0.h should be created using the configuration utility 13504DCFG. For more infor- mation on 13504DCFG, see the 13504DCFG Configuration Program User Manual, document number X19A-B-008-xx available at www.erd.epson.com.

7.Open the S1D13504 workspace.

From the Tornado tool bar, select File->Open Workspace...->Existing->Browse... and select the file “x:\13504\8bpp\13504.wsp” (or “x:\13504\16bpp\13504.wsp”).

8.Add support for single line comments.

The WindML v2.0 display driver source code uses single line comment notation, “//”, rather than the ANSI conventional comments, “/*...*/”.

To add support for single line comments follow these steps:

a.In the Tornado “Workspace Views” window, click on the “Builds” tab.

b.Expand the “8bpp Builds” (or “16bpp Builds”) view by clicking on the “+” next to it. The expanded view will contain the item “default”. Right-click on “default” and select “Properties...”. A “Properties:” window will appear.

c.Select the “C/C++ compiler” tab to display the command switches used in the build. Remove the “-ansi” switch from the line that contains “-g -mpen- tium -ansi -nostdinc -DRW_MULTI_THREAD”.

(Refer to GNU ToolKit user's guide for details)

9.Compile the VxWorks image.

Select the “Builds” tab in the Tornado “Workspace Views” window.

Right-click on “8bpp files” (or “16bpp files”) and select “Dependencies...”. Click on “OK” to regenerate project file dependencies for “All Project files”.

Right-click on “8bpp files” (or “16bpp files”) and select “ReBuild All(vxWorks)” to build VxWorks.

10.Copy the VxWorks file to the diskette.

From a command prompt or through the Windows interface, copy the file “x:\13504\8bpp\default\vxWorks” (or “x:\13504\16bpp\default\vxWorks”) to the bootable disk created in step 4.

11.Start the VxWorks demo.

Boot the target PC with the VxWorks bootable diskette to run the UGLDEMO auto- matically.