Page 8

Epson Research and Development

 

Vancouver Design Center

 

 

Example Installation

Installation for Hitachi D9000 and ETMA ODO

Follow the procedures from your Hitachi D9000 manual and download the following to the D9000 platform:

1.Download SEIKO EPSON’s common interface FPGA code (ODO.RBF) to the EEPROM of the D9000 system.

2.Download the Windows CE binary ROM image (NK.BIN) to the FLASH memory of the D9000 system.

Installation for CEPC Environment

Windows CE v2.0 can be loaded on a PC using a floppy drive or a hard drive. The two methods are described below:

1.To load CEPC from a floppy drive:

a.Create a DOS bootable floppy disk.

b.Edit CONFIG.SYS on the floppy disk to contain the following line only. device=a:\himem.sys

c.Edit AUTOEXEC.BAT on the floppy disk to contain the following lines. mode com1:9600,n,8,1

loadcepc /B:9600 /C:1 /D:2 c:\wince\release\nk.bin

d.Copy LOADCEPC.EXE from c:\wince\public\common\oak\bin to the bootable floppy disk.

e.Confirm that NK.BIN is located in c:\wince\release.

f.Reboot the system from the bootable floppy disk.

2.To load CEPC from a hard drive:

a.Copy LOADCEPC.EXE to the root directory of the hard drive.

b.Edit CONFIG.SYS on the hard drive to contain the following line only. device=c:\himem.sys

c.Edit AUTOEXEC.BAT on the hard drive to contain the following lines.

mode com1:9600,n,8,1

loadcepc /B:9600 /C:1 /D:2 c:\wince\release\nk.bin

d.Confirm that NK.BIN is located in c:\wince\release.

e.Reboot the system from the hard drive.