EQQE009I EQQE012E
|EQQE009I READY QUEUE LAST VALUE V1
|NEW READY OPERATIONS V2
|NEW STARTED OPERATIONS V3
|NEW COMPLETED OPERATIONS V4
|SELECT WINNER CALLS V5
|ACCESS JS CALLS V6
|ACCESS JOBLIB CALLS V7
|USER EXIT 001 CALLS V8
|USER EXIT 002 CALLS V9
|Explanation: This message is issued together with message EQQE008I. See the explanation for EQQE008I for
|details about when it is used.
|The meanings of variables V1 through V9 are as follows:
|V1 Size of the ready list queue when the message is issued
|V2 Number of operations whose status changed to ready (R, *, or A) since the last message
|V3 Number of operations whose status changed to started since the last message
|V4 Number of operations whose status changed to completed since the last message
|V5 Number of times the WSA task was called to select a 'winner' operation since the last message
|V6 Number of times the JS VSAM was accessed to read JCL since the last message
|V7 Number of times the JOBLIB PDS was accessed to read JCL since the last message
|V8 Number of times the User Exit 001 was called since the last message
|V9 Number of times the User Exit 002 was called since the last message
|System action: Normal TME 10 OPC processing continues.
|User response: None.
EQQE011E ETT FAILED TO ADD
ADID
FOR TRIGGERING EVENT
TRIG
NO ACTIVE APPLICATION
DESCRIPTION IN AD DATABASE
Explanation: ETT was triggered by an event but could not add the associated application because there was no
active application description in the AD database.
System action: The associated application was not added by ETT, but ETT processing continues normally.
Problem determination: Check the ETT criteria to make sure that the triggering event identifies an active application
description.
User response: Correct the ETT criteria table or the AD database.
EQQE012E ETT FAILED TO ADD
ADID
FOR TRIGGERING EVENT
TRIG
UNABLE TO ALLOCATE NECESSARY
STORAGE
Explanation: TME 10 OPC was unable to allocate storage needed to build the tables required when adding an
application (occurrence) to the current plan.
System action: The associated application was not added by ETT, but ETT processing continues normally.
Problem determination: Check the region size allocated to the TME 10 OPC started task.
User response: Contact your system programmer.
System programmer response: Increase the region for the TME 10 OPC started task.
84 TME 10 OPC Messages and Codes