EQQZ170E EQQZ174W
EQQZ170E TME 10 OPC CODE LEVEL VERIFICATION FAILED
CODE LEVEL OF THE SSX CONTROL BLOCK IS
SSXLEV
CODE LEVEL OF THE EQQMAJOR MODULE IS
MCALEV
CODE LEVEL OF THE
SSCM
MODULE IS
SSCMLEV
Explanation: TME 10 OPC initialization has determined that the SSX control block, the EQQMAJOR module and the
EQQSSCMx load module are on different service levels. This is not supported.
System action: TME 10 OPC initialization fails.
System programmer response: Verify that TME 10 OPC is using the correct load library. If the SSX control block
and the EQQMAJOR load module are on different code levels, modify the OPCOPTS statement, specifying the
BUILDSSX keyword. If the EQQSSCMx and the EQQMAJOR load modules are on different code levels, modify the
OPCOPTS statement, adding or changing the SSCMNAME keyword.
After making appropriate changes, restart the TME 10 OPC subsystem.
EQQZ171E MERGE PARAMETER IS NOT SUPPORTED. OLD SSX AND NEW SSX ARE NOT FOR THE SAME
FMID
CODE LEVEL OF THE NEW SSX CONTROL BLOCK IS
SSXLEV
CODE LEVEL OF THE OLD SSX CONTROL BLOCK IS
OLDLEV
Explanation: The MERGE parameter of the BUILDSSX keyword is only supported when the old SSX control block
was built for the same FMID as the current EQQMAJOR load module.
System action: TME 10 OPC initialization fails.
System programmer response: Change the BUILDSSX keyword to specify BUILDSSX(REBUILD).
EQQZ172I SSX BLOCK OF VERSION
SSXLEV
SUCCESSFULLY BUILT
Explanation: The
BUILDSSX
keyword was specified in the OPCOPTS control statement, and TME 10 OPC has
successfully verified that the EQQSSCM load module is of the correct version. A new SSX control block has been
built and will be used by this TME 10 OPC address space.
System action: The TME 10 OPC Address Space initialization continues.
EQQZ173I SSX BLOCK OF VERSION
SSXLEV
SUCCESSFULLY RESTORED
Explanation: The
BUILDSSX
keyword was specified in the OPCOPTS control statement, and TME 10 OPC has
successfully restored the previous version of the SSX block as the operative version.
This message is only issued when the SSX block was rebuilt by the TME 10 OPC address space using the
BUILDSSX
keyword, and when the address space is about to terminate.
The
SSXLEV
variable indicates the code level of the SSX that is restored. The restored SSX will be used by all
TME 10 OPC functions while the TME 10 OPC subsystem is inactive.
System action: The TME 10 OPC Address Space termination continues.
EQQZ174W OLD AND NEW SSX CONTROL BLOCK ARE ON THE SAME LEVEL,
SSXLEV
Explanation: The
BUILDSSX
keyword was specified in the OPCOPTS control statement and a new SSX block has
been successfully built. However, the new and the old SSX control block are at the same code level.
System action: TME 10 OPC initialization continues.
System programmer response: If this message is expected, modify the OPCOPTS statement, removing the
BUILDSSX keyword.
If this message is not expected, verify that load modules used by TME 10 OPC are coming from correct load libraries.
After making appropriate changes, restart the TME 10 OPC subsystem.
428 TME 10 OPC Messages and Codes