EQQN088E EQQN092E
EQQN088E NMM WAS UNABLE TO SWITCH TO NEXT JOB TRACKING LOG DATA SET,
DDNAME
DDNAME
, BECAUSE IT HAS NOT YET BEEN ARCHIVED.
Explanation: TME 10 OPC was unable to use the next job tracking log in a situation where current job tracking log
can no longer be used.
System action: The Normal Mode Manager subtask is stopped and the current plan is no longer available.
Problem determination: Review earlier messages in the message log data set to determine why the next job
tracking log has not been archived.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: Stop TME 10 OPC. Ensure that TME 10 OPC is authorized to update all job
tracking log data sets defined by currently specified (or defaulted) values of the JTLOGS and DUAL keywords of the
JTOPTS initialization statement. Reallocate any job tracking log data sets that had output errors. After making
necessary corrections, restart TME 10 OPC.
EQQN090I THE JOB TRACKING LOG DATA SET DEFINED BY DDNAME
DDNAME
HAS BEEN COPIED TO THE
JOB TRACKING LOG ARCHIVE DATA SET
Explanation: The Job Tracking Log Archiver task has successfully copied a data set to the archive data set.
System action: Normal TME 10 OPC processing continues.
User response: None.
EQQN091I THE LOG ARCHIVER TASK WAS UNABLE TO COPY THE DATA SET DEFINED BY DDNAME
DDNAME
TO THE JOB TRACKING LOG ARCHIVE DATA SET
Explanation: An error prevented the Job Tracking Log Archiver task from copying a job tracking log data set to the
archive data set.
System action: The Job Tracking Log Archiver task terminates. The current plan updating tasks continue but if the
Log Archiver task problem is not corrected, TME 10 OPC will eventually run out of available job tracking log data sets.
Problem determination: Review earlier messages in the message log data set to determine what prevented the Log
Archiver task from copying current log data set.
TME 10 OPC administrator response: Contact your system programmer.
System programmer response: Stop TME 10 OPC. Ensure that TME 10 OPC is authorized to read all job
tracking log data sets defined by currently specified (or defaulted) values of the JTLOGS and DUAL keywords of the
JTOPTS initialization statement. Reallocate any job tracking log data sets that had output errors. After making
necessary corrections, restart TME 10 OPC.
EQQN092E AN I/O ERROR OCCURRED WHILE ATTEMPTING TO UPDATE THE JOB TRACKING LOG ARCHIVE
DATA SET. THE ARCHIVER TASK IS ENDING. SYNAD MESSAGE FOLLOWS:
SYNMSG
Explanation: An I/O error occurred when the JT log archiver task tried to write a log record to the job tracking
archive log data set.
System action: The JT log archiver task ends. The current plan updating tasks continue but if the JT log archiver
task problem is not corrected, TME 10 OPC will eventually run out of available job tracking log data sets.
TME 10 OPC administrator response: Contact your system programmer.
Problem determination: The SYNAD routine collects information such as jobname, stepname, unit address, device
type, ddname, operation, error description, and access method. The SYNADAF macro is used to extract this
information. For a detailed description of the layout refer to the appropriate decoumentation for the MVS/DFP product
installed on this MVS/ESA system.
System programmer response: Stop TME 10 OPC. If necessary, allocate a new job tracking log archive data set
and copy the old data set to the new data set. After making corrections, restart TME 10 OPC.
226 TME 10 OPC Messages and Codes