EQQ0350E EQQ0354W
EQQ0350E PERIOD START LATER THAN LAST BACKUP TIME
Explanation: Reporting can only be requested for time periods less recent than the last old current plan. The old
current plan is a backup copy of the current plan and is updated either after every certain number of events (specified
at installation time) or during daily planning.
System action: The daily planning program is terminated.
User response: Change the parameter value for the trial type in the SYSIN statement for the daily planning
program. Use the Daily Planning dialog to get the current value for period start on the Producing Trial Daily Plan
panel.
EQQ0351W PERIOD END LATER THAN ******** **.** LAST BACKUP TIME
Explanation: Reporting can only be requested for time periods less recent than the last old current plan. The old
current plan is a backup copy of the current plan and is updated either after every certain number of events (specified
at installation time) or during daily planning.
System action: The daily planning program is terminated.
User response: Change the parameter value for the trial type in the SYSIN statement for the daily planning
program. Use the Daily Planning dialog to get the current value for period end on the Producing Trial Daily Plan
panel.
EQQ0352W NO DEP IN ******** **************** **.** FOR ******** **************** **.**
Explanation: An inconsistency in the long-term plan file dependencies has been found. Predecessor data for the
first occurrence in the message selects the second occurrence which either:
Is already completed or deleted
No longer exists
Has the corresponding successor dependency marked as “deleted.”
System action: The daily planning program prints a dump of the erroneous long-term plan file records on the
EQQDUMP file, issues an error message, marks the dependency on the long-term plan file as “completed,” and
continues processing.
User response: Document prior actions concerning the involved occurrences, and then contact your system
programmer.
System programmer response: Collect the dump, the error message, and other relevant information for this
occurrence. Then contact your IBM representative.
EQQ0353I APPL **************** ******** **.** NOT IN SUMMARY OF COMPL APPL
Explanation: The application had an invalid completion date and could not be added to the summary table of
completed applications (maximum 28 days). The reason may be an incorrect day given at IPL of the system.
System action: The daily planning program continues processing.
User response: None.
EQQ0354W NUMBER OF OPEN INTERVALS EXCEEDS MAXIMUM FOR WORKSTATION **** PLANNING MAY
BE AFFECTED
Explanation: The current plan record is larger than 32 KB (kilobytes).
System action: The daily planning program continues processing, and ignores the extra open intervals.
User response: Use the Work Station Description dialog to decrease the number of open intervals.
450 TME 10 OPC Messages and Codes