EQQD114E EQQD119I
EQQD114E OPC/ESA COULD NOT DELETE MIGRATED DATASET
DSN
. APPLICATION IS
AD
, INPUT ARRIVAL
IS
IA
, OPERATION NUMBER IS
OPNO
, AND JOBNAME IS
JNM
.
Explanation: When OPC/ESA tried to locate the dataset, it resided on logical volume MIGRAT. OPC/ESA has tried
to recall the dataset and waited the time given in the CHSMWAIT keyword. As the dataset has not been recalled
within the time given, the catalog management status for the dataset and the operation will be set to error.
System action: The catalog management action ends in error for this operation.
User response: Delete the dataset manually. Also, inform your system programmer that OPC/ESA was not able to
delete a migrated dataset.
System programmer response: Increase the time interval in the CHSMWAIT keyword.
EQQD115I THE CATALOG MANAGEMENT EXIT
XIT
TERMINATED ABNORMALLY WHEN IT WAS CALLED. SEE
THE SYSMDUMP DATASET FOR MORE INFORMATION. THE EXIT HAS BEEN MARKED AS NOT
EXECUTABLE, AND WILL NOT BE CALLED AGAIN.
Explanation: An abend has occurred in the exit. TME 10 OPC has flagged the exit as not executable, and will not
try to call it again.
System action: Processing continues. The exit will not be called again.
User response: Contact your system programmer.
System programmer response: Analyze the dump generated for the problem, and correct the failing exit. When
you have corrected the errors, load the exit again by stopping and then starting the catalog management subtask, or
by stopping and starting the TME 10 OPC address space.
EQQD116I THE CATALOG MANAGEMENT ACTION FOR DATASET
DSN
HAS BEEN DISCARDED.
APPLICATION IS
AD
, INPUT ARRIVAL IS
IA
, OPERATION NUMBER IS
OPNO
, AND JOBNAME IS
JNM
.
Explanation: Due to a dialog status change, the catalog management action for this dataset has been discarded.
System action: OPC/ESA updates the dataset status to D (discarded).
User response: None.
EQQD118I A JOBLOG FOR JOB
JNM
HAS ARRIVED AT THE CONTROLLER. CATALOG MANAGEMENT IS
NOT ACTIVE AT THE CONTROLLER SO THE JOBLOG IS DISCARDED.
Explanation: A joblog or joblog status record has been sent to the controller but catalog management has not been
activated at the controller so joblogs can not be received.
System action: The joblog is discarded. Processing continues.
System programmer response: Specify CATMGT=Y in the OPCOPTS statement for the controller if you want to
store joblogs.
EQQD119I A DATASET COLLECTION EVENT HAS BEEN ENCOUNTERED. THE EVENT WILL NOT BE
PROCESSED BECAUSE THE CATALOG MANAGEMENT FUNCTION IS NOT ACTIVE AT THE
CONTROLLER. JOBNAME IS
JNM
, JOB ID IS
JID
AND NODE NAME IS
NODE
Explanation: An event describing datasets to be managed for a job by catalog management has been passed to the
controller. However, catalog management is not active at the controller. The event information will not be saved by
the controller, and no catalog management will be performed for this operation.
System action: The event is discarded. No further catalog management action is taken for the operation.
System programmer response: If catalog management should be active, specify CATMGT(YES) in the controller's
OPCOPTS statement, and then restart the controller.
Chapter 6. EQQDnnn Messages 69