EQQM388W EQQM392E
|EQQM388W VERIFY JCL FOR POSSIBLE INCONSISTENCIES
|Explanation: One of the following situations has occurred:
|At least one step staus of FLUSH was detected. Restarting from this step may be possible; however verification
|for the status of datasets used in this step is recommended.
|At least one IEF377I message was found in the joblog. This means that in the previous run the job successfully
|allocated the data set, but did not manage to catalog it.
|System action: None.
|System programmer response: Change the JCL if necessary. If flushed steps have been detected then
|EQQM373W messages will show which ones they are. If there are catalog problems, then EQQM378W messages
|will indicate which data sets are involved. See the description for EQQM378W for details on what action should be
|taken.
EQQM390I OPC/ESA NEEDS A JOBLOG TO PROCESS THE COMMAND. IT HAS BEEN REQUESTED
Explanation: You have tried to make a catalog management request or browse-joblog request on an TME 10 OPC
system activated for step-level restart and where the needed joblogs will be retrieved at the time of your request.
TME 10 OPC has requested the tracker to retrieve the joblog.
System action: The panel will be redisplayed with this information message.
User response: Wait for the request to complete. Check the joblog-retrieval Status field or wait to get a
TSO-broadcast that the request has Completed. Then reenter your dialog request.
System programmer response: None.
EQQM391I A JOBLOG IS NEEDED TO PROCESS THE COMMAND. IT IS NOT YET RETRIEVED
Explanation: You have tried to make a catalog management or browse-joblog request on an TME 10 OPC system
activated for step-level restart and where the required joblogs will be retrieved at the time of your request. TME 10
OPC has initiated a request to the tracker to retrieve the job log but the request has not yet been processed.
System action: The panel will be redisplayed with this information message.
User response: Wait for the request to complete. Check the joblog-retrieval Status field or wait to get a
TSO-broadcast that the request has Completed. Then reenter your dialog request.
System programmer response: None.
EQQM392E A JOBLOG IS NEEDED TO PROCESS THE COMMAND. COULD NOT BE RETRIEVED
Explanation: You have tried to make a catalog management or browse-joblog request on an TME 10 OPC system
activated for step-level restart and where the required joblogs will be retrieved at the time of your request. TME 10
OPC has initiated a request to the tracker but has received an error return code from the tracker attempting retrieval
of the job log.
System action: If you requested Catalog Management actions or Restart and TME 10 OPC has collected dataset
information, the dataset list panel will be displayed with this error message, rather than the expected Step list panel. If
you requested Browse-Joblog nothing will be displayed.
User response: TME 10 OPC can not perform step-level restart for this job and you can not browse the joblog.
Contact your system programmer to find out why the joblog could not be retrieved.
System programmer response: The TME 10 OPC tracker has not been able to retrieve the SYSOUT for this job.
The tracker tries to retrieve it either by reading held SYSOUT or by calling the joblog-retrieval user exit. Check the
value of the JOBLOGRETRIEVAL keyword. There will be messages in the tracker message log, EQQMLOG, that
help to further diagnose the problem.
Chapter 16. EQQMnnn Messages 199