EQQW051E EQQW055I
EQQW051E JOB
JOBNAME
COULD NOT BE SUBMITTED. REASON: AUTHORITY FOR RUSER

USER

,
SUPPLIED BY USER EXIT EQQUX001, COULD NOT BE DETERMINED
Explanation: A user ID was supplied by the submit exit, EQQUX001, and the job was then sent using the
submit/release dataset to the DRVP macro. The buffer pool was successfully built.
System action: The job is not submitted and normal TME 10 OPC processing continues.
User response: Make sure that the supplied userid is defined to the external security manager.
EQQW052E THE EVENT DATASET, DDNAME
DDNAME
, LRECL

LRECL

IS INVALIDLY DEFINED. DATASET IS
NOT USABLE.
Explanation: The event dataset referenced by ddname
DDNAME
has been allocated with an invalid logical record
length.
System action: Event writer initialization fails.
Problem determination: An event dataset must have a logical record length (LRECL) not less than 100 and not
greater than 32000. Check that the LRECL is within the supported range.
System programmer response: Stop TME 10 OPC, reallocate the dataset and restart TME 10 OPC.
EQQW053E THE SYSOUT ARCHIVING EXIT, EQQUX005, ABENDED AND HAS BEEN DISABLED
Explanation: The sysout archiving exit, EQQUX005, abended while processing a job's SYSOUT dataset. TME 10
OPC has disabled the exit for this type of function for the remainder of the TME 10 OPC session.
System action: MVS recovery/termination is requested to generate a dump. The exit will not be called again for this
particular function but TME 10 OPC processing continues.
Problem determination: Review the SYSLOG dataset, the TME 10 OPC message log, and the dump dataset to
determine the cause of the error.
System programmer response: Correct the error and, if necessary, restart the JCC subtask using the modify
commands or restart the TME 10 OPC tracker.
EQQW054I THE JOB COMPLETION CHECKER IS BEING STARTED FOR CATALOG MANAGEMENT ACTIONS
Explanation: The job completion checker has been started to perform catalog management step level restart
functions, because the JOBLOGRETRIEVAL keyword in the OPCOPTS initialization statement has been set to a
value other than NONE and the JCC was not requested to be started by initialization statements set by the user. This
message is issued either when TME 10 OPC is started, or when the JCC subtask is started with an MVS modify
command.
System action: The Job Completion Checker is started.
User response: None.
EQQW055I THE JOBLOG FOR
JOBNAME
JOBNUM
DOES NOT CONTAIN ALL DATASETS REQUIRED BY THE
OPC/ESA CATALOG MANAGEMENT FUNCTION
Explanation: The Job Completion Checker has discovered that the joblog for the current job does not contain all
joblog datasets needed by TME 10 OPC. The required datasets are JESJCL and JESYSMSG, and one or both of
them are missing.
System action: The Job Completion Checker processing continues.
System programmer response: Verify that either the JES installation setup or the job does not suppress JESJCL
and/or JESYSMSG files from being created.
304 TME 10 OPC Messages and Codes