EQQA300E EQQA308E
|EQQA300E VALID DATA IS A NUMBER 1 - 255
|Explanation: Data entry error; “Data Entry Errors” on page 2.
EQQA301E THERE MUST BE AT LEAST ONE OPERATION IN AN APPLICATION
Explanation: The application has no operations. You must specify at least one operation.
System action: The system waits for you to respond.
User response: Specify one or more operations for the application.
EQQA302E PREDECESSOR OPERATION
PO
IS NOT FOUND FOR OPERATION
OP
Explanation: The predecessor operation (predecessor operation number
po
) was not found for the operation
(operation number
op
). An internal predecessor operation must exist within the application.
System action: The system waits for you to respond.
User response: Enter an existing operation number.
EQQA303E OPERATION
OP
IS NOT CONNECTED TO APPLICATION
Explanation: The operation (operation number
op
) has no predecessor or successor connections to the application.
System action: The system waits for you to respond.
User response: Enter or change an internal predecessor to establish a correct application link.
EQQA304E OPERATION
OP
SPECIFIES WORK STATION
OPWS
, WHICH IS NOT FOUND
Explanation: The operation (operation number
op
) of this application specifies a workstation (workstation name
opws
), which was not found in the workstation description database.
System action: The system waits for you to respond.
User response: Enter an existing workstation name, or use the workstation description dialog to define the
workstation name.
EQQA305E DEPENDENCIES INCLUDING OPERATION
OP
FORM A LOOP
Explanation: A loop was detected in the operation (operation number
op
) dependency network which must be
corrected. For example, operation 10 has operation 5 its as predecessor, and operation 5 has operation 10 its as
predecessor.
System action: The system waits for you to respond.
User response: Correct the loop found with these internal predecessors.
EQQA306E VALID-FROM DATE LATER THAN VALID-TO DATE
Explanation: Data entry error; see “Data Entry Errors” on page 2.
When modifying an application, the valid-from date cannot be changed to a date later than the valid-to date.
EQQA307E OPERATION INPUT ARRIVAL TIME MUST BE SPECIFIED FOR A TIME JOB
Explanation: Data entry error; see “Data Entry Errors” on page 2.
An operation input arrival time must be specified if the time-dependent job option is specified as YES.
EQQA308E JOB SETUP OPERATION
OP
MUST HAVE A CPU SUCCESSOR
Explanation: The job setup operation (operation number
op
) must have a CPU successor operation.
System action: The system waits for you to respond.
User response: Enter the job setup operation number as a CPU predecessor number.
24 TME 10 OPC Messages and Codes