EQQZ007E EQQZ012E
EQQZ007E OPC/ESA JOBNAME
JOBNAME
IS NOT A VALID SUBSYSTEM NAME
Explanation: The TME 10 OPC subsystem task module, EQQMAJOR, has been incorrectly invoked.
System action: The EQQMAJOR program is terminated.
System programmer response: Change the name of the TME 10 OPC subsystem started task to one of the
subsystem names defined in SYS1.PARMLIB, then reissue the start command.
|EQQZ008E THE OPC/ESA INITIALIZATION PROGRAM, EQQINITC, HAS NOT BEEN SUCCESSFULLY
|EXECUTED. THE OPC/ESA SUBSYSTEM IS UNABLE TO START
Explanation: The TME 10 OPC subsystem could not start because the required CSA resident control blocks could
not be located or were invalid. These control blocks are built during IPL by the EQQINITC program.
System action: Processing continues.
Problem determination: Check that the currently active IEFSSN
xx
member of SYS1.PARMLIB defines the TME 10
OPC subsystem correctly. Check also that EQQINITC is present in SYS1.LINKLIB or in a library in the LNKLST
xx
concatenation of libraries. Review the master console messages issued during IPL.
System programmer response: Correct all errors, then restart TME 10 OPC after an IPL of the MVS system.
EQQZ010E MEMBER
MEMBER
CANNOT BE FOUND IN PARAMETER LIBRARY
Explanation: The parameter library member
MEMBER
could not be found in the library defined by the EQQPARM
DD statement.
System action: The TME 10 OPC subtask that issues this message is terminated.
Problem determination: Check that the EQQPARM DD statement is correctly defined. Check also that the
OPCOPTS initialization statement is correctly defined.
System programmer response: Correct all errors, then restart the failing subtask.
EQQZ011E PARAMETER LIBRARY MEMBER
MEMBER
IS EMPTY
Explanation: There are two possibilities:
The parameter library member
MEMBER
exists in the library defined by the EQQPARM DD statement, but there
are no records in the member.
When running EQQEVPGM, the dataset referenced by the SYSIN DD statement is empty.
System action: The TME 10 OPC subtask that issues this message is terminated.
Problem determination: Check that the EQQPARM DD statement is correctly defined, or, when using EQQEVPGM,
that the SYSIN DD statement uses the correct dataset name. Check also that the OPCOPTS initialization statement
is correctly defined.
System programmer response: Correct all errors, then restart the failing subtask.
EQQZ012E I/O ERROR READING PARAMETER LIBRARY MEMBER
MEMBER
Explanation: The parameter library member
MEMBER
could not be read from the library defined by the EQQPARM
DD statement.
System action: The TME 10 OPC subtask that issues this message is terminated.
Problem determination: Review earlier messages in the TME 10 OPC message log to determine the exact reason
for this message.
System programmer response: Correct all errors, then restart the failing subtask.