EQQZ076E EQQZ084E
EQQZ076E DB2SYSTEM KEYWORD NOT SPECIFIED
Explanation: The OPCOPTS or the BATCHOPTS initialization statement defines OPERHISTORY(YES) but the
statement does not specify the DB2SYSTEM keyword.
System action: TME 10 OPC is terminated.
System programmer response: Edit the OPCOPTS or BATCHOPTS statement and either remove the
OPERHISTORY keyword or specify the name of a DB2 system in the DB2SYSTEM keyword.
|EQQZ077W OPERHISTORY IS NO BUT RELATED PARAMETERS ARE SPECIFIED: IGNORED
Explanation: The OPCOPTS initialization statement specifies the DB2SYSTEM or CONTROLLERTOKEN
parameter, either without specifying the OPERHISTORY keyword or with OPERHISTORY set to NO.
System action: Processing continues.
|System programmer response: Check whether the history function is intentionally disabled or whether the
|OPERHISTORY keyword was omitted. If the OPERHISTORY keyword was omitted, add it, setting the value to YES.
EQQZ078I DB2SYSTEM

DB2SYS

IS NOT AVAILABLE
Explanation: The DB2 system specified in the DB2SYSTEM keyword of the OPCOPTS initialization statement is not
active.
System action: Processing continues, but the history function is not available.
System programmer response: Start the DB2 system.
EQQZ079I DB2SYSTEM

DB2SYS

IS AVAILABLE
Explanation: The DB2 system specified in the DB2SYSTEM keyword of the OPCOPTS statement has been started.
The TME 10 OPC history function is now available.
System action: Processing continues.
System programmer response: None.
EQQZ080I A STOP OPC/ESA COMMAND HAS BEEN RECEIVED
Explanation: The TME 10 OPC address space has received an operator stop command.
System action: TME 10 OPC posts all active subtasks for termination and terminates when all subtasks have
terminated.
User response: None.
EQQZ083E INVALID OPC/ESA JOBNAME
JOBNAME
. NAME MUST BE 4 CHARACTERS OR LESS
Explanation: The TME 10 OPC subsystem task module, EQQMAJOR, has been incorrectly invoked.
System action: The EQQMAJOR program is terminated.
System programmer response: Change the name of the TME 10 OPC subsystem started task to one of the
subsystem names defined in SYS1.PARMLIB, then reissue the start command.
EQQZ084E UNABLE TO ATTACH OPC/ESA SUBTASK
SUBTASK
Explanation: An error occurred when the TME 10 OPC subsystem attempted to attach the subtask

SUBTASK

.
System action: TME 10 OPC continues processing.
Problem determination: Review earlier messages in the TME 10 OPC message log and SYSLOG datasets to
determine the exact reason for this message. One possibility is that TME 10 OPC is being started in a region that is
too small.
System programmer response: Correct all errors, then restart TME 10 OPC.