EQQY229E EQQY236E
EQQY229E SETUP FOR OPERATION:

POP

IN APPLICATION:

PID

NOT COMPLETE
Explanation: A SELECT JCLPREP was done without completion of the listed operation.
System action: None.
User response: Correct the error and resubmit the job. operation in the application matches the specification given
in the message text. A blank means that no value is specified.
System action: The application description is rejected.
User response: Correct the input file and resubmit the job.
EQQY233E FAILED TO ADD OPERATOR INSTRUCTION FOR AD:
AD
, OPERATION:
OP
REASON CODE
RS
Explanation: An operator instruction has been written to the database with temporary information. The update of it,
with the correct information about which operation it belongs to, has failed.
There are two possible reasons as given by
RS
:
The read of the temporary instruction failed.
The update failed.
System action: The operator instruction is rejected.
Problem determination: The message log contains a detailed description of the error. If the output is to an TME 10
OPC subsystem, then these descriptions are found in the message log of the subsystem.
User response: Resubmit the job with only this operator instruction. If the problem occurs again, report the error to
your IBM representative.
EQQY234E FAILED TO DELETE OPERATOR INSTRUCTION:
KEY
. REASON CODE:
RS
Explanation: The deletion of an operator instruction failed.
There could be two reasons for the failure as given by
RS
:
A read of the operator instructions fails.
The delete operation fails.
System action: None.
Problem determination: The message log also contains a detailed description of the error.
User response: Check if the operator instruction still exists there, by allocating the output file to an TME 10 OPC
subsystem. If it is, delete it using the OI dialog. If the problem occurs again, report the error to your IBM
representative.
EQQY235E NO OPERATION SPECIFIED, SPECIFY WSID, OPNO AND/OR JOBN
Explanation: An OISTART statement, which does not identify the owning operation, is received from the input file.
System action: The operator instruction is rejected.
User response: Correct the input file and resubmit the job.
EQQY236E NO SETUP SESSION HAS YET BEEN ESTABLISHED FOR THE CURRENT OPERATION
Explanation: You tried to issue an INSERT request for resource JCLPREP without first issuing a successful
SELECT JCLPREP request.
System action: The update of JCL variable values is rejected.
User response: Correct the PIF user program and try again.
394 TME 10 OPC Messages and Codes