EQQRM23W EQQRM28W
EQQRM23W A SPECIAL RESOURCE DEVIATION COULD NOT BE DETERMINED FROM A RODM OBJECT.
RESOURCE NAME IS
NAME
Explanation: A RODMOPTS statement specifies that a special resource deviation quantity should be updated by a
field in a RODM object. However, the value of the field is not within the valid range of special resource deviations.
The valid range is -999999 – 999999.
System action: The special resource quantity is not changed. The RODM subtask continues normal processing.
System programmer response: Verify that the RODM object has been correctly updated. Verify that the
RODMOPTS statement refers to the correct RODM object.
EQQRM24W SUBSCRIBE FOR RODM OBJECT
NAME
FAILED. RC IS
RC
, REASON IS
RSN
Explanation: A non-zero return code was returned by a RODM system when the RODM subtask called the RODM
API to add a notify subscription.
System action: The RODM subtask continues normally. If the RODM object is modified later, the RODM subtask
will not be notified and the corresponding TME 10 OPC resource will not be updated.
System programmer response: Ensure that the current field in the RODM object has a notify subfield. Refer to
RODM Programming Guide
, SC31-6130, for more information about return codes and reason codes used by the
RODM API.
EQQRM25I SUBSCRIBE FOR RODM OBJECT
NAME
WAS SUCCESSFUL
Explanation: A zero return code was returned by a RODM system when the RODM subtask called the RODM API
to add a notify subscription.
System action: The RODM subtask continues normally. If the RODM class is modified later, the RODM subtask will
be notified and the corresponding TME 10 OPC resource will be updated.
System programmer response: None.
EQQRM26W SUBSCRIBE FOR RODM CLASS
NAME
FAILED. RC IS
RC
, REASON IS
RSN
Explanation: A non-zero return code was returned by a RODM system when the RODM subtask called the RODM
API to add a notify subscription.
System action: The RODM subtask continues normally. If the RODM class is modified later, the RODM subtask will
not be notified and the corresponding TME 10 OPC resource will not be updated.
System programmer response: Ensure that the current field in the RODM class has a notify subfield. See
RODM
Programming Guide
, SC31-6130, for more information about return codes and reason codes used by the API.
EQQRM27I SUBSCRIBE FOR RODM CLASS
NAME
WAS SUCCESSFUL
Explanation: A zero return code was returned by a RODM system when the RODM subtask called the RODM API
to add a notify subscription.
System action: The RODM subtask continues normally. If the RODM class is later modified, the RODM subtask will
be notified and the corresponding TME 10 OPC resource will be updated.
System programmer response: None.
|EQQRM28W SUBSCRIBE FOR RODM OBJECT
NAME
FAILED. RC IS
RC
, REASON IS
RSN
TME 10 OPC WILL
|RETRY EVERY 3 MINUTES
|Explanation: A nonzero return code was returned by a RODM system when the RODM subtask called the RODM
|API to add a notify subscription for a RODM object.
|System action: The RODM subtask continues normally. TME 10 OPC will try again after three minutes to add the
|notify subscription for the RODM object.
|System programmer response: None.
246 TME 10 OPC Messages and Codes