EQQC013W EQQC022I
EQQC013W AUTOMATIC RECOVERY REQUEST FAILED, CANNOT ALLOCATE BUFFERS
Explanation: A storage allocation error prevented automatic job recovery from checking whether or not recovery
should be performed for the job that ended in error. This message may be followed by message EQQC045I with
reason code 50, which identifies the job checked by automatic job recovery.
System action: No recovery attempt is made and the job remains ended in error.
User response: Use the ended-in-error list of the Modify Current Plan dialog to decide whether or not a new
automatic job recovery attempt should be made for the job that ended in error.
System programmer response: Stop TME 10 OPC and then restart it in a larger region.
EQQC014W AUTOMATIC RECOVERY REQUEST FAILED DUE TO I/O ERROR
Explanation: An I/O error prevented automatic job recovery from determining whether or not recovery should be
performed for the job that has ended in error. This message may be followed by message EQQC045I with reason
code 50, which identifies the job checked by automatic job recovery.
System action: No recovery attempt is made and the job remains ended in error.
Problem determination: Review the earlier messages in the TME 10 OPC message log for a message issued for
the I/O error.
User response: Use the ended-in-error list of the Modify Current Plan dialog to decide whether or not a new
automatic job recovery attempt should be made for the job that ended in error.
System programmer response: Refer to the associated I/O error message for guidance.
EQQC021W NO AUTOMATIC RECOVERY TEST BECAUSE NO ERROR INFORMATION IN JNT RECORD
Explanation: When a job fails, error information about the failing operation is saved in the job-name-table (JNT)
record. Automatic job recovery was initiated but could not determine if recovery should be performed for the failed job
because no error information was available in the JNT record. This message is followed by message EQQC045I with
reason code 50, which identifies the job checked by automatic job recovery.
System action: No recovery attempt is made and the job remains ended-in-error.
Problem determination: Review the TME 10 OPC message log for inconsistencies at the time the job ended in
error. Also review the event dataset for the completion of the job. Refer to

TME 10 OPC Diagnosis Guide and

Reference

for the layout of the event dataset record.
User response: If any recovery actions by automatic job recovery were required for the job that failed, the actions
must be initiated manually. Use the Modify Current Plan dialog to initiate the actions.
If you use automatic job recovery together with catalog management and have defined the RESSTEP parameter of
the RECOVER statement, specify STEPEVENTS(ALL) on the EWTROPTS statement. Otherwise automatic job
recovery and catalog management will not be invoked.
System programmer response: Check the TME 10 OPC message log for any messages issued at the time the job
ended in error to determine why no JNT record exists.
EQQC022I AUTOMATIC RECOVERY ACTION POSTPONED FOR OPERATION
OPNO
IN APPLICATION
ADID
Explanation: When the automatic recovery for this operation was about to start, TME 10 OPC found that a catalog
management action for this operation was in progress. The automatic recovery for this operation will be postponed
until catalog management has finished its processing for the operation.
System action: The recovery attempt is postponed.
User response: None.
Chapter 4. EQQCnnn Messages 33