EQQX430E EQQX434E
EQQX430E THE PREDECESSOR APPLICATION ID IS REQUIRED BUT NOT AVAILABLE
Explanation: The predecessor application ID is a required parameter in the request. It is not specified.
System action: If this is a request to the program interface function, the request is rejected and control is returned
with the return code set to error.
Problem determination: The diagnostic file (with ddname EQQDUMP) contains a dump of the control blocks
validated when the error was detected.
User response: Specify the predecessor application ID as an argument in the program interface request.
EQQX431E
AST
IS NOT A VALID STATUS CODE
Explanation: Status
AST
is not a valid status code. The codes supported are V, T, S, and C.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the record and the position of the error.
User response: Enter a valid status code and resubmit the job. If you cannot find a valid reason for the error,
contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If the
error persists, contact your IBM representative.
EQQX432E
AEC
IS NOT A VALID CODE FOR ADDING FUNCTION
Explanation: Code
AEC
specifies an updating function that is not supported.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the record and the position of the error.
User response: Check the entered data and if the error occurred in batch, resubmit the job. If you cannot find a
valid reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If the
error persists, contact your IBM representative.
EQQX433E A MAXIMUM OF 100 EXTERNAL PREDECESSORS ARE ALLOWED
Explanation: No more than 100 external predecessors may be specified in an application.
System action: The request to write the record is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the record and the position of the error.
User response: Check the entered data and if the error occurred in batch, resubmit the job. If you cannot find a
valid reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause and the error persists, contact your IBM representative.
EQQX434E
IAD
IAT
AD
CANNOT HAVE A DEPENDENCY ON ITSELF
Explanation: An occurrence cannot be dependent on itself.
System action: A dump of the record is written to the diagnostic file (EQQDUMP).
User response: Check your dependency specifications.
374 TME 10 OPC Messages and Codes