EQQ0540E EQQ0546W
EQQ0540E SPECIFIED PRINTOUT PERIOD GREATER THAN 4 YEARS
Explanation: You are requesting a printout of the long-term plan dataset for a period of more than four years, but
the long-term plan may have a span of up to four years only.
System action: The job is terminated.
User response: Request a printout for a period less than four years.
EQQ0541E LONG TERM PLAN EMPTY - NO HEADER RECORD
Explanation: A long-term plan batch function is trying to reference a long-term plan dataset that has no header. The
long-term plan is either empty or in error.
System action: The job is terminated.
User response: Create a long-term plan using the Long-Term Planning dialog.
EQQ0542W OCCURRENCE FOR APPLICATION
AD
WITH RUNDAY
RUNDAY
AND INPUT ARRIVAL
RTIME
COULD NOT BE FOUND IN THE LONG TERM PLAN. PREDECESSORS / SUCCESSORS FOR THE
APPLICATION MAY HAVE TO BE MANUALLY COMPLETED
Explanation: The actual occurrence has been deleted from the long-term plan, probably by a non-TME 10 OPC
function.
System action: A new current plan is created, but the daily plan program ends with a return code of 4.
User response: Check the current plan that is created, and complete/delete dependencies to make the plan
consistent.
EQQ0543E LTP END DATE - LTP START DATE > 4 YEARS
Explanation: A long-term plan must not be longer than four years.
System action: The job is terminated.
User response: Respecify the long-term plan end date.
EQQ0544E LTP EXISTS - OCCURRENCES SELECTED BY DAILY PLAN
Explanation: Occurrences in the long-term plan have been selected by daily planning and might have been included
in the current plan. It is not possible to create the long-term plan without first refreshing it using the Service Function
dialog.
System action: The job is terminated.
User response: Select another long-term plan function.
EQQ0545E START DATE AFTER END DATE
Explanation: The start date must be earlier than the end date.
System action: The job is terminated.
User response: Specify correct dates and then resubmit the job.
EQQ0546W THE PREDECESSOR

PRED

WITH RUNDAY

PREDAY

AND INPUT ARRIVAL

PTIME

, FOR
APPLICATION
AD
IN THE LONG TERM PLAN COULD NOT BE FOUND. THE APPLICATION
AD
WITH RUNDAY
RUNDAY
AND INPUT ARRIVAL
RTIME
MAY HAVE TO BE MANUALLY COMPLETED
OR DELETED
Explanation: The actual occurrence has been deleted from the long-term plan, probably by a non-TME 10 OPC
function.
System action: A new current plan is created, but the daily plan program ends with a return code of 4.
User response: To make the current plan consistent, check the current plan that is created, and complete/delete the
occurrence for the application.
462 TME 10 OPC Messages and Codes