EQQX115E EQQX118E
EQQX115E TSO SERVICE FACILITY RC:
XSSRC
, RSNC:
XSSRS
, ABEND:
XSSAB
Explanation: The TSO Service facility, IKJEFTSR, which is used for communication between the dialog and the
TME 10 OPC subsystem, gave an error return code. The field RC gives the IKJEFTSR return code (
XSSRC
):
8Confirms that the requested function is terminated as a result of the user pressing ATTN (attention).
12 The invoked function has abended; the RSNC field then contains the IKJEFTSR reason code, and the
ABEND field contains the abend code.
20 There is a problem with the IKJEFTSR parameter list; and
XSSRS
is the reason code for the problem.
System action: The request is rejected.
Problem determination: Use the return code, reason code, and abend code to determine the cause of the error.
For more information, refer to the documentation of IKJEFTSR for the currently active MVS/ESA system.
User response: If the return code is other than 8 (a result of your pressing ATTN), leave the dialog and then try
again. If the error persists, contact your system programmer.
System programmer response: Ensure that the correct load module library is accessed and that the dataset
contains the correct version of the TME 10 OPC modules. If the error persists, collect information in the form of the
sequence of actions leading to the error, and if possible, the data it may be dependent on. Then contact your IBM
representative.
EQQX116E ERROR IN SUBSYSTEM INTERFACE, RETURN CODE:
XRC
Explanation: An error occurred in the subsystem interface. Return code
XRC
provides debugging information for
IBM personnel.
System action: The request is rejected.
User response: Contact your system programmer.
System programmer response: Ensure that the correct load module library is accessed and that the dataset
contains the correct version of the TME 10 OPC modules. If the error persists, collect information in the form of the
sequence of actions leading to the error, and if possible, the data it may be dependent on. Then contact your IBM
representative.
EQQX117E ERROR IN EQQMINOR ROUTINE, RETURN CODE:
XRC
Explanation: An error, with return code
XRC
, occurred in the EQQMINOR routine. The return code is returned from
the MVS subsystem interface routine at a subsystem call request.
System action: The request is rejected.
Problem determination: Use the return code to determine the cause of the error. For more information, refer to the
documentation of return codes from the IEFSSREQ macro for the currently active MVS/ESA system.
User response: Contact your system programmer.
System programmer response: Ensure that the correct load module library is accessed and that the dataset
contains the correct version of the TME 10 OPC modules. If the error persists, collect information in the form of the
sequence of actions leading to the error, and if possible, the data it may be dependent on. Then contact your IBM
representative.
EQQX118E ERROR IN LOGON ROUTINE. RETURN CODE:
XSSRC
. REASON CODE
XSSRS
Explanation: An error, with return code
XSSRC
and reason code
XSSRS
, occurred in the logon routine. Return
code
XSSRC
and reason code
XSSRS
provide debugging information for IBM personnel.
System action: The request is rejected.
User response: Contact your system programmer.
System programmer response: Ensure that the correct load module library is accessed and that the dataset
contains the correct version of the TME 10 OPC modules. If the error persists, collect information in the form of the
sequence of actions leading to the error, and if possible, the data it may be dependent on. Then contact your IBM
representative.
332 TME 10 OPC Messages and Codes