EQQE055W EQQE058W
EQQE055W THE EVENT MANAGER HAS IGNORED THE FOLLOWING SUBMIT EVENT RECORD BECAUSE NO
MATCHING OPERATION WAS FOUND IN THE CURRENT PLAN:
EXITREC
Explanation: The Event Manager’s work queue contains an incorrect submit event. No operation in the current plan
dataset matches the operation defined by the event record. This submit event record is created for work being
scheduled on one of the systems in this Controller's OPC configuration by another Controller having the same name.
System action: The Event Manager continues normal processing.
Problem determination: Check if the Current Plan has changed significantly since the job defined in the event
record was submitted. Check if the submit event is old, and was sent by an TME 10 OPC subsystem that has been
inactive a long time.
System programmer response: If you cannot determine the reason for this message, contact your IBM
representative.
EQQE056W THE EVENT MANAGER HAS IGNORED THE FOLLOWING INVALID EVENT RECORD:
EXITREC
Explanation: An invalid event record has been found on the Event Manager’s work queue. The most likely error is
that the last 4 bytes of the record do not contain the TME 10 OPC character string EQQ3. It is also possible that the
first 3 characters of the job number field do not contain the character string JOB.
System action: The incorrect event record is returned to the Event Manager’s free queue without any further
processing.
TME 10 OPC administrator response: Note the job name and job number in the exit record. If necessary, set the
correct status for this job manually.
System programmer response: Save the TME 10 OPC message log dataset (EQQMLOG) containing this message
and then contact your IBM representative.
EQQE057W AN INVALID EVENT QUEUE ENTRY HAS CAUSED OPC/ESA TO IGNORE THE FOLLOW. EVENT:
EVENT HEADER:

EVNTHDR

EVENT RECORD:
EXITREC
Explanation: An invalid event queue entry has been found on the Event Manager’s work queue. The Event
Manager could not determine the origin of the event. Each event must come from one of sixteen possible event
datasets on each TME 10 OPC node. In the current event queue entry, either the event dataset number or the
TME 10 OPC node number is not valid.
System action: The incorrect event record is returned to the Event Manager’s free queue without any further
processing.
System programmer response: Save the TME 10 OPC message log dataset containing this message and then
contact your IBM representative.
EQQE058W THE EVENT MANAGER HAS IGNORED THE FOLLOWING USER DEFINED EVENT RECORD
BECAUSE THE WORK STATION NAME
WSNAME
IS NOT RECOGNIZED:
EXITREC
Explanation: An invalid user-defined event record has been found on the Event Manager’s work queue. The
workstation name in the current event record does not match any workstation definition in the current plan dataset.
System action: The incorrect event record is returned to the Event Manager’s free queue without any further
processing.
System programmer response: Determine if any user program generates events for an undefined workstation or if
a new current plan containing an additional workstation must be created.
Chapter 8. EQQEnnn Messages 91