EQQRM17W EQQRM22W
EQQRM17W CONNECTION LOST TO RODM SUBSYSTEM:
NAME
Explanation: TME 10 OPC has lost the connection to a RODM subsystem.
System action: Processing continues. The status for all resources being monitored by the named RODM subsystem
will be set to inactive, and the values of the corresponding TME 10 OPC resource fields will be set according to the
RODMLOST values in the RODMOPTS statements. Attempts to reconnect to this RODM subsystem will be initiated
every 5 minutes.
User response: None.
EQQRM18E INVALID TRANSLATION VALUE

TYPE VALUE

SPECIFIED FOR OPC RESOUCE
NAME
Explanation: A RODMOPTS statement specifies a translate value that is invalid.
System action: RODM subtask initialization fails and the controller is shutdown.
System programmer response: Specify a valid value in the TRANSLATE ordered list and restart the controller.
EQQRM19E INVALID RODMLOST VALUE

VALUE

SPECIFIED FOR OPC RESOURCE
NAME
Explanation: A RODMOPTS statement specifies a RODMLOST value that is invalid.
System action: RODM subtask initialization fails and the controller is shutdown.
System programmer response: Specify a valid value in the RODMLOST keyword and restart the controller.
EQQRM20E DESTINATION UNKNOWN

NAME

Explanation: A RODMOPTS statement specifies a destination unknown to TME 10 OPC.
System action: RODM subtask initialization fails and the controller is shutdown.
System programmer response: Specify a valid destination name and restart the controller.
EQQRM21W THE AVAILABILITY OF A SPECIAL RESOURCE CANNOT BE DETERMINED FROM A RODM
OBJECT. RESOURCE NAME IS
NAME
Explanation: A RODMOPTS statement specifies that the availability of a special resource should be updated by a
field in a RODM object. TME 10 OPC cannot determine whether the special resource is available or not because the
value of the field is not Y, N, or a value that can be translated to Y or N.
System action: The availability of the special resource is not changed. The RODM subtask continues normal
processing.
System programmer response: Verify that the RODM object has been correctly updated. Verify that the
RODMOPTS statement refers to the correct RODM object.
EQQRM22W A SPECIAL RESOURCE QUANTITY COULD NOT BE DETERMINED FROM A RODM OBJECT.
RESOURCE NAME IS
NAME
Explanation: A RODMOPTS statement specifies that a special resource quantity should be updated by a field in a
RODM object. However, the value of the field is not within the valid range of special resource quantities. The valid
range is 0–999 999.
System action: The special resource quantity is not changed. The RODM subtask continues normal processing.
System programmer response: Verify that the RODM object has been correctly updated. Verify that the
RODMOPTS statement refers to the correct RODM object.
Chapter 21. EQQRMnn Messages 245