EQQW767W EQQW770E
EQQW767W THE EVENT CREATION ROUTINE DETECTED THAT THE IATUX29 WAS GENERATED AGAINST A
JES3 LEVEL THAT DOES NOT MATCH THE CURRENT EXECUTING JES3 LEVEL
Explanation: The level of the JES3 macros used to generate the TME 10 OPC IATUX29 does not match the level
of the active JES3 system.
System action: The event creation routine continues to create event records. The event records may contain invalid
tracking information, causing the corresponding operation status to be inaccurate.
Operator response: If necessary, set the correct operation status manually.
System programmer response: Apply the IATUX29 and IATUX19 again, and make sure that the appropriate
maclibs are used in the SYSLIB concatenation. If you are assembling the IATUX29 and IATUX19 outside the JES3
SMP-environment, make sure you have the SMPMTS dataset top concatenated in the SYSLIB concatenation.
EQQW768W AN I/O ERROR OCCURRED ON THE EQQSTC DATA SET WHEN THE SUBMITTOR TASK WAS
READING. THE SYNAD ERROR MESSAGE WAS:
SYNMSG
Explanation: The submittor task encountered an input/output error reading the EQQSTC, the started task temporary
proclib file.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
The corresponding operation is set to status E.
Problem determination: The SYNAD routine collects information such as jobname, stepname, unit address, device
type, ddname, operation, error description, and access method. The SYNADAF macro is used to extract this
information. For a detailed description of the layout refer to the appropriate documentation for the MVS/DFP product
installed on this MVS/ESA system.
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: This is probably a hardware error. Contact your IBM representative.
EQQW769W AN ABEND OCCURRED WHEN THE SUBMITTOR TASK WAS READING ON THE EQQSTC DATA
SET. THE ABEND CODE WAS:
ABCODE
Explanation: The submittor task got an abend when reading EQQSTC, the started task temporary proclib file.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
The corresponding operation is set to status E.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: This is probably a hardware error. Contact your IBM representative.
EQQW770E EQQSTC DDNAME IS MISSING
Explanation: The submittor task could not find the EQQSTC ddname in the JCL.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
System programmer response: Add an EQQSTC ddname to the TME 10 OPC JCL procedure and specify an
empty dataset that is allocated on the JES proclib concatenation.
For more information, refer to

TME 10 OPC Installation Guide

.
324 TME 10 OPC Messages and Codes