EQQW505I EQQW511E
EQQW505I THE WORK STATION ANALYZER TASK HAS STARTED
Explanation: The initialization of the workstation analyzer has completed and the workstation analyzer is about to
start processing.
System action: TME 10 OPC processing continues.
System programmer response: None.
EQQW506E OPC/ESA WAS UNABLE TO ALLOCATE STORAGE TO PROCESS MEMBER
MEMBER
OF
EQQJBLIB
Explanation: The workstation analyzer was attempting to build a VSAM dataset record to be inserted in the JCL
repository dataset, but it was unable to do so because of insufficient virtual storage.
System action: The operation remains in ready status. The workstation analyzer is unable to submit the job to JES.
User response: Submit the job manually.
System programmer response: Stop TME 10 OPC and then restart in a larger region.
EQQW507W OPC/ESA WAS UNABLE TO SAVE JOB
MEMBER
IN THE JS DATASET FOR APPL.
APPL
Explanation: An error occurred when the workstation analyzer was trying to update the JCL repository dataset.
System action: The job will be submitted to JES, but the JCL repository dataset would not be correctly updated.
Problem determination: Review earlier messages in the TME 10 OPC message log to determine the exact reason
for this message.
System programmer response: Correct all errors and then restart the workstation analyzer.
EQQW510E WS ANALYZER WAS UNABLE TO READ OR UPDATE CURRENT PLAN JNT RECORD FOR: JOB =
JOBNAME
, APPLICATION =
APPL
, INPUT ARRIVAL =

ARRTIME

Explanation: The workstation analyzer encountered a VSAM error when reading or updating the current plan
dataset.
System action: The workstation analyzer continues normal processing with the next ready operation.
Problem determination: Review earlier messages in the TME 10 OPC message log and SYSLOG datasets to
determine the exact cause of this error.
System programmer response: Correct all errors and then restart the workstation analyzer.
EQQW511E WS ANALYZER WAS UNABLE TO RELEASE JOB
JOBNAME
(
JOBNUM
) FROM HOLD
Explanation: The workstation analyzer was unable to communicate successfully with JES while trying to release job
JOBNAME
(
JOBNUM
) from hold.
System action: The hold status of the current job is not changed. The workstation analyzer continues normal
processing.
Problem determination: Check that JES is executing normally.
Operator response: Check that the job is still held by JES. If it is, enter an appropriate operator command to
release the job from hold.
Chapter 30. EQQWnnn Messages 315