EQQW760E EQQW762E
EQQW760E AN I/O ERROR OCCURRED ON THE EQQSTC DATA SET WHEN THE SUBMITTOR TASK WAS
WRITING THE JCL FOR STC
STCNAME
. THE SYNAD ERROR MESSAGE WAS:
SYNMSG
Explanation: The submittor task encountered an input/output error writing to EQQSTC, the started task temporary
proclib file. A SYNAD error routine was given control and issued an error message.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
The corresponding operation is set to status E.
Problem determination: The SYNAD routine collects information such as jobname, stepname, unit address, device
type, ddname, operation, error description, and access method. The SYNADAF macro is used to extract this
information. For a detailed description of the layout refer to the appropriate documentation for the MVS/DFP product
installed on this MVS/ESA system.
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: This is probably a hardware error. Contact your IBM representative.
EQQW761E AN ABEND OCCURRED WHEN THE SUBMITTOR TASK WAS WRITING THE JCL FOR STC
STCNAME
ON THE EQQSTC DATA SET. THE ABEND CODE WAS:
ABCODE
Explanation: The submittor task got an ABEND when writing EQQSTC, the started task temporary proclib file. An
ABEND exit routine was given control and issued an ABEND code.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
The corresponding operation is set to status E.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: See

MVS/ESA Message Library: System Codes

for an explanation of the ABEND
code, and take appropriate action.
EQQW762E AN I/O ERROR OCCURRED ON THE EQQSTC DATA SET WHEN THE SUBMITTOR TASK WAS
STOWING THE MEMBER FOR STC
STCNAME
. THE SYNAD ERROR MESSAGE WAS:
SYNMSG
Explanation: The submittor task encountered an input/output error during a STOW to EQQSTC, the started task
temporary proclib file. A SYNAD error routine was given control and issued an error message.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
The corresponding operation is set to status E.
Problem determination: The SYNAD routine collects information such as jobname, stepname, unit address, device
type, ddname, operation, error description, and access method. The SYNADAF macro is used to extract this
information. For a detailed description of the layout refer to the appropriate documentation for the MVS/DFP product
installed on this MVS/ESA system.
Save the MLOG from the TME 10 OPC subsystem.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
Save the SYSLOG from the primary system console.
System programmer response: This is probably a hardware error. Contact your IBM representative.
322 TME 10 OPC Messages and Codes