EQQ0100E EQQ0183W
EQQ0100E APPLICATION DESCRIPTION DATA SET IN USE, TRY LATER
Explanation: You have attempted to access the application description dataset, but it is being used by another user.
System action: The job is terminated.
User response: Try again later.
EQQ0105W APPLICATION DESCRIPTION
ADID
NOT FOUND
Explanation: You have attempted to read the application description
ADID
but this application description ID does
not exist in the application description database.
System action: The job continues processing.
User response: Enter an existing application description ID or use the application description dialog to create a new
application description, and then resubmit the job. If the message was issued from a batch job, create the application
description, then resubmit the job.
EQQ0170W APPL:
APPL
- VALIDATION FAILED. REASON
REASON
, POSITION
POSITION
Explanation: During mass update of the application description database, the changes that were made have caused
application description
APPL
to become invalid.
REASON
indicates the reason why validation of the application
description failed; and
POSITION
indicates the failing position in hexadecimal form within the record.
System action:
APPL
is not updated. The job continues with the next application description.
User response: Analyze the reason for the error. (See Chapter 36, “Reason Codes” on page 481 for a list of the
reason codes and their meanings.) If necessary, use the application description dialog to correct the application
description.
EQQ0172W APPL:
APPL
- PREDECESSOR
OPID
NOT FOUND
Explanation: The internal predecessor
OPID
could not be found for the application description
APPL
.
System action: The application description
APPL
is not activated. The daily planning program continues processing
but without planning this application. The job continues processing but without planning this application.
User response: Use the application description dialog to check and correct the dependencies between operations.
EQQ0175W APPL:
APPL
- OPERATION
OPID
IS ISOLATED FROM OTHER OPS IN NET
Explanation: There is more than one network. This is not allowed.
System action: The application description
APPL
is not activated. The daily planning program continues processing
but without planning this application. The job continues processing but without planning this application.
User response: Use the Application Description dialog to check and correct the dependencies between operations.
EQQ0176W APPL:
APPL
- OPERATION
OPID
IS INVOLVED IN A DEPENDENCY LOOP
Explanation: There is a dependency loop in the network. This message is issued for all operations involved in the
dependency loop, and for all operations preceding the loop.
System action: The application description
APPL
is not activated. The daily planning program continues processing
but without planning this application. The job continues processing but without planning this application.
User response: Use the application description to check and correct the dependencies between operations.
EQQ0183W APPL:
APPL
- PREP OP
OPID
HAS NO SUCCEEDING CPU OP
Explanation: You have specified an operation at a workstation which uses the job setup function, but the operation
OPID
does not have an immediately succeeding processor operation with the same job name.
System action: The application description
APPL
is not activated. The daily planning program continues processing
but without planning this application.
User response: Use the application description dialog to check and correct the dependencies between operations.
Chapter 34. EQQnnnn Messages 439