EQQSU22E EQQSU24W
EQQSU22E UNABLE TO ACCESS THE EQQEVDS FILE FOR REQUEST TYPE
DQETYPE
ON WORKSTATION
WSNAME
Explanation: The submit task was unable to execute a submit checkpoint request for the reason stated. Request
type can be one of:
J0 Request for submit checkpoint sequence number
J1 Job submit checkpoint request
J2 STC start checkpoint request
WTO Message checkpoint request
System action: The submit task continues normal processing.
Problem determination: Review earlier messages in the message log to determine the cause of the error.
System programmer response: If necessary, stop TME 10 OPC, take corrective actions and then restart TME 10
OPC.
EQQSU23E NO FREE SPACE IN EQQEVDS HEADER RECORD FOR REQUEST TYPE
DQETYPE
ON
WORKSTATION
WSNAME
Explanation: The submit task was unable to execute a submit checkpoint request because all workstation entries in
the the event data set header record are used. Request type can be one of:
J0 Request for submit checkpoint sequence number
J1 Job submit checkpoint request
J2 STC start checkpoint request
WTO Message checkpoint request
System action: The Submit task continues normal processing.
Problem determination: The maximum number of workstations that can be checkpointed by this EQQEVDS is
indicated in message EQQSU12I. If you have more workstations defined for this destination than can be
checkpointed, you should reallocate the EQQEVDS with a larger logical record length, refer to

TME 10 OPC

Installation Guide

for more details.
System programmer response: If necessary, stop TME 10 OPC, scratch and reallocate the EQQEVDS with a
larger LRECL and then restart TME 10 OPC.
EQQSU24W WORKSTATION
WSNAME
IS NOT PRESENT IN THE EQQEVDS HEADER RECORD
Explanation: The Job Submit task could not remove a workstation name from the event data set header record
because the name is not present.
System action: The Job Submit task continues normal processing.
System programmer response: None.
266 TME 10 OPC Messages and Codes