EQQW756W EQQW759W
EQQW756W THE OPC/ESA STARTED TASK FILE, DDNAME = EQQSTC, IS NOT EMPTY
Explanation: EQQSTC, the started task temporary proclib file, is not empty.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Save the JCL from the failing job or started task.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
System programmer response: Check that the dataset allocated to the EQQSTC ddname is an empty partitioned
dataset.
EQQW757W THE OPC/ESA STARTED TASK FILE, DDNAME = EQQSTC, HAS WRONG LRECL OR WRONG
BLOCK SIZE
Explanation: EQQSTC, the started task temporary proclib file, was allocated with a different record length than 80 or
an invalid block size.
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Save the JCL from the failing job or started task.
Run the AMASPZAP utility specifying ABSDUMP ALL on the dataset, and save the output.
System programmer response: Check that the dataset allocated to the EQQSTC ddname is an empty partitioned
dataset with record length 80.
EQQW758W THE SUBMITTOR TASK DETECTED THAT THE STC
STCID
IS STILL IN JES3 INPUT SERVICE
(STARTING)
Explanation: The started task has not passed the JES3 input service phase.
This message is repeated every ten minutes.
System action: The submittor task will not submit started tasks until the STC has passed JES3 input service, but will
continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Save the SYSLOG from the primary system console.
Produce a dynamic console dump of the TME 10 OPC address space. Ensure that CSA is part of the SDUMP
option.
System programmer response: None.
EQQW759W THE SUBMITTOR TASK COULD NOT HANDLE STC
STCNAME
Explanation: The started task was queued to the submittor queue, SUBQ. The STC could not be submitted
because of errors (indicated by previous messages).
System action: The submittor task will not submit started tasks, but will continue to submit batch jobs and WTOs.
Problem determination:
Save the MLOG from the TME 10 OPC subsystem.
Produce a dynamic console dump of the TME 10 OPC address space. Ensure that CSA is part of the SDUMP
option.
User response: Manually set the corresponding operation to the correct status.
System programmer response: Investigate the MLOG, and look for other messages that explain the error.
Chapter 30. EQQWnnn Messages 321