EQQM381I OPC/ESA HAS FOUND NO INCONSISTENCIES IN THE JCL FOR A RESTART
Explanation: TME 10 OPC has investigated the JCL for restart, and has found no errors. The operation may be
restarted.
System action: None.
User response: Leave the panel with END command to save the JCL and initiate catalog management for the
operation, cancel the restart using the CANCEL command, or edit the JCL using JCL primary command.
EQQM382W THE OPERATION CANNOT BE RESTARTED WITHOUT CHANGING THE JCL
Explanation: TME 10 OPC has investigated the JCL for restart, and has found errors. Use the JCL primary to
determine whether JCL updates are required
System action: The system waits for you to respond.
User response: Either edit and change the JCL, or cancel the restart of the operation.
EQQM383E THE ABSOLUTE GDG NUMBER IS MISSING FOR THIS DATASET
Explanation: TME 10 OPC was unable to find the absolute GDG number for the dataset.
System action: None.
User response: Check to ensure that the GDG base exists, and that the GDG level has not been deleted or that the
dataset has not been filtered out by a user exit.
EQQM384W THE RESTART STEP IS INSIDE AN IF/THEN/ELSE CLAUSE
Explanation: Unpredictable results may occur when the selected restart step is within an IF-THEN-ELSE clause.
System action: None.
User response: Check to ensure that the step selected is the correct step and that the IF-THEN-ELSE clause is
understood.
EQQM385E NUMBER OF STEPS FOUND IN THE JOB LOG INCONSISTENT
Explanation: The number of steps found in the job log is not consistent with the number of steps reported by the
tracker when the job ended.
System action: Processing continues.
User response: Contact your system programmer.
System programmer response: Keep a copy of the event dataset from the tracker where the job executed, the
current plan, and the JCL repository, and contact your IBM representative.
EQQM386W THE GDG BASE IS MISSING FOR THIS DATASET
Explanation: TME 10 OPC was unable to find the GDG base for the dataset at job submit time.
System action: None.
User response: Check to ensure that the GDG name is defined correctly. The GDG may be created during the life
time of the job so this may not be an error.
EQQM387W CM ACTION FOR THIS JOB IS
OCHCNO
SO GDG CANNOT BE RESOLVED
Explanation: The job to be rerun contains GDG datasets but catalog management action for the operation is none.
The absolute GDG value is missing therefore missing and the GDG dataset cannot be resolved.
System action: The JCL is presented to the user with the GDG dataset specification unchanged.
User response: Change the DD statement manually. When using steplevel restart for operations containing GDG
datasets the catalog management action should be set to D or Y (D is recommended).