EQQ0555W EQQ0561W
EQQ0555W WS ID
WSID
NOT FOUND WITHIN ANY APPLICATION
Explanation: When printing an “operations using particular work stations” report during an application description
PRINT, the specified workstation name does not appear in any application description.
System action: The job continues processing.
User response: Specify the correct workstation name and then resubmit the job.
EQQ0556W ADID
ADID
< 16 CHARACTERS, IT WAS PADDED WITH BLANKS
Explanation: The indicated application ID was read from the user dataset and was found to be shorter than 16
characters. It is padded with blanks up to the 16th character. This message is only issued if the input dataset has a
variable record length.
System action: The application print program continues processing.
User response: Check if all applications wanted were printed.
EQQ0557W OWNER ID

OWID

NOT FOUND WITHIN ANY APPLICATION
Explanation: When printing an “owner ID” report type or displaying the long-term plan for one owner, the specified
owner ID does not appear in any application description.
System action: The job continues processing.
User response: Specify the correct owner ID and then resubmit the job.
EQQ0558W NO AD RECORDS FOUND THAT MEET THE REQUIRED SPECIFICATIONS
Explanation: No application description records were found that met the required specifications.
System action: The job is terminated.
User response: Check that the application description database is not empty, that if a date is specified it is correct,
and that the IDs specified are correct. Correct the errors and then resubmit the job.
EQQ0559E SORT OUT OF SEQUENCE
Explanation: The application print program found a record that was not sorted in the proper sequence.
System action: The job is terminated.
User response: Contact your system programmer.
System programmer response: Check the sort program messages to determine the cause of the error. If you
cannot determine the cause and if the error persists, contact your IBM representative.
EQQ0560E SORT FAILED
Explanation: Sort was invoked on an application description printout work dataset, but the program issued return
code 16.
System action: The job is terminated.
User response: Contact your system programmer.
System programmer response: Check the sort program messages to determine the cause of the problem. Correct
the error and then resubmit the job.
EQQ0561W APPLICATION
ADID
NOT VALID ON
DATE
Explanation: A detailed application description printout is requested for a specific application, valid on a specific
date, but no such description exists in the application description database.
System action: The job continues processing.
User response: Check if the date is correctly specified and if an application description which is valid on that date
should exist.
464 TME 10 OPC Messages and Codes