EQQY211E EQQY223E
EQQY211E TOO MANY
SIGN
START DAYS ENTERED, AT MOST
NUM
ARE ACCEPTED
Explanation: The application can only be selected
NUM
times for one run cycle.
System action: The application description is rejected.
User response: Correct the input file and resubmit the job. If you need to select more days, repeat the run cycle the
necessary number of times.
EQQY221E NO OPERATION IN
PID
MATCHES THE PREDECESSOR SPECIFICATION SUCCESSOR KEY:
KEY
,
SUCCESSOR OPERATION:
OP
PREDECESSOR SPECIFICATION JOBNAME:
JOB
, WORK STATION:
WS
Explanation: No operation in the predecessor application matches the specification given in the message text. A
blank means that no value is specified. A predecessor operation can be specified by workstation name, operation
number, or job name, or a combination of these. If the predecessor is required by another application, or another
occurrence of the same application, an application ID is also required.
System action: The application description is rejected.
User response: Correct the input file and resubmit the job.
EQQY222E MORE THAN ONE OPERATION IN
PID
MATCHES THE PREDECESSOR SPECIFICATION
SUCCESSOR KEY:
KEY
, SUCCESSOR OPERATION:
OP
PREDECESSOR SPECIFICATION:
JOBNAME:
JOB
, WORK STATION:
WS
Explanation: More than one operation in the predecessor application matches the specification given in the message
text. A blank means that no value is specified. A predecessor operation can be specified by workstation name,
operation number, or job name, or a combination of these. If the predecessor is required by another application or
another occurrence of the same application, an application ID is also required.
System action: The application description is rejected.
User response: Correct the input file and resubmit the job.
EQQY223E FAILED TO UPDATE
KEY
, OPERATION
OP
WITH PREDECESSOR INFORMATION PREDECESSOR:
PID
, OPERATION:
POP
. REASON CODE
RS
Explanation: An application has been written to the database with temporary predecessor information. The update
of the predecessor section to add the correct information, has failed.
There are three possible reasons as given by
RS
:
The read of the application to be updated, failed.
The update write failed.
The update failed because the predecessor could not be identified. The application description might have been
updated previously.
System action: The application description is rejected.
Problem determination: The message log of the subsystem contains a detailed description of the error.
User response: Resubmit the job with only this application description. If the problem occurs again, report the error
to your IBM representative.
392 TME 10 OPC Messages and Codes