EQQW771W EQQW777W
EQQW771W THE JCL FOR STC
JOBNAME
WILL NOT BE SUBMITTED BECAUSE SUBMIT RECORD IS TOO
OLD
Explanation: Started task JCL records in a submit/release dataset are older than the limit defined by the SKIPTIME
and SKIPDATE keywords in the EWTROPTS statement.
System action: The old records are not processed. The event writer continues to read the submit/release dataset.
Operator response: Restart the corresponding operation, if necessary.
EQQW772W THE WTO WITH JOBNAME
JOBNAME
WILL NOT BE ISSUED BECAUSE SUBMIT RECORD IS TOO
OLD
Explanation: A WTO message in a submit/release dataset is older than the limit defined by the SKIPTIME and
SKIPDATE keywords in the EWTROPTS statement.
System action: The old message is not processed. The event writer continues to read the submit/release dataset.
Operator response: Restart the corresponding operation, if necessary.
EQQW775I APPLICATION:
ADID
OP£:
OPNO
WITH INPUT ARRIVAL:
IA
AND JOBNAME:
JOBNM
ON WORK
STATION:
WSNAME
HAS BEEN STARTED. OPERATION TEXT:
OPTEXT
Explanation: A WTO operation has been started by TME 10 OPC.
This message is for your information only. It can be intercepted and interpreted in a customer-defined manner.
System action: None.
User response: None.
EQQW776I APPLICATION:
ADID
OP£:
OPNO
WITH INPUT ARRIVAL:
IA
AND JOBNAME:
JOBNM
ON WORK
STATION:
WSNAME
HAS PASSED DEADLINE:
DEADL
OPERATION TEXT:
OPTEXT
Explanation: An operation has passed its deadline.
This message is for your information only. It can be intercepted and interpreted in a customer-defined manner, for
example to automate termination.
System action: None.
User response: None.
EQQW777W THE EVENT CREATION ROUTINE DETECTED THAT THE JES2 EXIT7 (EQQEXIT) IS ON A HIGHER
RMID LEVEL THAN THE OPC/ESA SUBSYSTEM MODULE EQQZEV2X
Explanation: The EQQEXIT macro used to generate the currently active JES2 EXIT7 is on a higher maintenance
level than the subsystem module EQQZEV2X.
System action: The event creation routine continues to create event records. The event records may contain invalid
tracking information, causing the corresponding operation status to be inaccurate.
Operator response: If necessary, set the correct operation status manually.
System programmer response: The EQQZEV2X is part of the EQQSSCMC load module, which is normally loaded
during IPL. To activate a new EQQSSCMC—until a planned IPL can be performed—specify
SSCMNAME(EQQSSCMC) in the OPCOPTS initialization statement and restart the tracker address space.
Chapter 30. EQQWnnn Messages 325