EQQJ548W EQQJ561E
EQQJ548W VARIABLE
VAR
IN TABLE

TABLE

COULD NOT BE UPDATED. REASON IS
RSN
Explanation: A SAVEVAR directive with ERRORACT=CONT was found during variable substitution. TME 10 OPC
tries to update the default value as requested in the SETVAR directive, but it was not possible for one of the following
reasons:
HELDLOCK Could not get ENQ lock necessary to access the variable.
NOTFOUND Variable/table did not exist in the table dataset
BADVNAME Variable/table is either an TME 10 OPC-supplied variable or a temporary variable. These variables
are never saved.
System action: Processing continues. The job is submitted as normal but next time the default value is requested
as input to variable substitution, it will not show the latest updated value.
User response: The value can be corrected by allowing a person with update access to the variable table to update
the default value manually in the JCL variable dialog.
EQQJ549E A SETUP PHASE DIRECTIVE AT LINE
LINE
OF
SCTN
REFERS TO A VARIABLE DEFINED FOR USE
AT SUBMIT
Explanation: The current job contains a JCL processing directive specifying PHASE=SETUP. TME 10 OPC could
not determine what action is requested by the statement because it refers to a JCL variable whose value will not be
determined until the submit phase.
System action: The system waits for you to respond.
User response: Enter the JCL Edit dialog and correct the incorrect statement. Then reenter the Ready List dialog
and retry JCL setup for this operation.
EQQJ550E Character
CHR
in position
POS
is invalid
Explanation: The value entered as a default value does not match the validation pattern defined for the variable.
System action: The system waits for you to respond.
User response: Enter the correct value.
EQQJ551E The value of the independent variable already exists
Explanation: The same value of the independent variable appears on two different rows of the dependency table.
System action: The system waits for you to respond.
User response: Correct or delete the values that you entered.
EQQJ560E MORE THAN 16 VARIABLES SPECIFIED IN SAVEVAR DIRECTIVE AT LINE
LINE
OF
SCTN
Explanation: The number of variables requested to be saved in a SAVEVAR directive is greater than 16.
System action: If the error occurs during submit, the current operation status is set to ended-in-error with error code
OJCV. Otherwise, the status is not changed.
User response: Split the SAVEVAR directive into multiple directives.
EQQJ561E TEMPORARY VARIABLE NAME
VAR
ALREADY USED FOR SUBSTITUTION IN JOB
JOBNAME
Explanation: A SETVAR directive requests creation of a temporary variable. There has been an earlier reference in
the job to the same name and it has been found in the TME 10 OPC Variable Table.
System action: If the error occurs during submit, the current operation status is set to ended-in-error with error code
OJCV. Otherwise, the status is not changed.
User response: Use another name for your temporary variable.
142 TME 10 OPC Messages and Codes