EQQW307E EQQW405E
EQQW307E SPECIFIED FROM-TIME LATER THAN TO-TIME
Explanation: Data entry error; see “Data Entry Errors” on page 2.
User response: Specify a to-time that is later than the from-time.
EQQW308E DUPLICATE WORK STATION CLOSED DATES EXIST IN TABLE
Explanation: Data entry error; see “Data Entry Errors” on page 2.
EQQW309I ALL WORK STATION CLOSED INFO MISSING, NO ACCESS TO DATA BASE
Explanation: Information about whether or not all workstations are closed for this date could not be retrieved
because you do not have access to the all-work-station-closed database.
System action: None.
User response: None.
EQQW400E WTO OPTION ONLY ALLOWED IF WORK STATION TYPE IS GENERAL
Explanation: Data entry error; see “Data Entry Errors” on page 2.
The WTO option is allowed if the workstation type is general, but not if the workstation type is computer or printer.
EQQW401E THE WTO OPTION IS MUTUALLY EXCLUSIVE WITH THE SPECIFIED OPTION
Explanation: Data entry error; see “Data Entry Errors” on page 2.
The WTO option is not allowed if the workstation option is job setup, task or splittable.
EQQW402E STARTED TASK OPTION ONLY ALLOWED IF WORK STATION TYPE IS CPU
Explanation: Data entry error; see “Data Entry Errors” on page 2.
Started Task option is allowed if the workstation type is Computer, but not if the workstation type is General or Printer.
EQQW403E THE STC OPTION IS MUTUALLY EXCLUSIVE WITH THE SPECIFIED OPTION
Explanation: Data entry error; see “Data Entry Errors” on page 2.
The STC option is not allowed if the workstation option is job setup, WTO, or splittable.
EQQW404E THIS DESTINATION REPRESENTS AN OPC/A V1R2 NEC SYSTEM
Explanation: The destination specified is defined as an OPC/A Version 1 Release 2 NEC system in the ROUTOPTS
initialization statement. Any work that should be transmitted to such a system must be handled by NJE.
System action: The workstation description is not updated.
System programmer response: If TME 10 OPC should initiate work at this destination, an TME 10 OPC tracker
must be started here. The ROUTOPTS initialization statement must be changed to reflect the new system type.
EQQW405E THIS DESTINATION IS NOT KNOWN TO OPC/ESA
Explanation: The destination specified is not defined to TME 10 OPC in the ROUTOPTS initialization statement.
System action: The workstation description is not updated.
User response: Verify that the destination is correctly specified.
System programmer response: All TME 10 OPC tracker systems connected to the controller must defined in the
ROUTOPTS initialization statement.