EQQWL21W EQQWL30E
EQQWL21W

EVENT

EVENT IGNORED FOR WORK STATION
WSID
Explanation: An event has been received that is not possible because of the status of the workstation.
You cannot change the status of a workstation to the status that it already has. For example, if a workstation already
has failed status, a failure event will produce this message.
System action: The event is ignored. The workstation status does not change.
User response: Verify that the TME 10 OPC status of the workstation is correct. If the status is incorrect, correct it
with the TME 10 OPC dialog.
EQQWL22I WORK STATION IS IN STATUS

STAT

Explanation: This message accompanies message EQQWL21W.
System action: None.
User response: None.
EQQWL23W WORK STATION
WSID
IS PENDING ONLINE. MANUAL ACTION REQUIRED
Explanation: An automatic online event has been received for the destination that this workstation represents.
Either the workstation status is offline and the WSOFFLINE activate action is MANUAL, or the workstation status is
failed and the WSFAILURE activate action is MANUAL.
This message is information only.
System action: The status of the workstation will not change until you activate it manually from the TME 10 OPC
dialog.
User response: If you want to activate the workstation, use the MCP Work Station communication dialog.
EQQWL24W A FAIL EVENT IS IGNORED. WORK STATION

XXXX

IS ALREADY OFFLINE
Explanation: A failure event has been received for an XCF workstation that has already been set to offline. Since
the offline event was received first, the workstation will not subsequently change status to failure.
System action: The event is ignored. The workstation status does not change. The WSOFFLINE actions will be
taken.
User response: Verify the reasons for the offline and failure events. If you wish different actions to be taken, review
your WSOFFLINE and WSFAILURE keywords and adjust them as necessary.
EQQWL30E LOOP IN ALTERNATE WORK STATIONS. FIRST WS IS:
WSID
Explanation: This workstation has been put in reroute mode. This workstation is part of a circular set of alternate
workstations. (For example, workstation A reroutes to B, B to C, and C to A.)
All of the other workstations in the circle are unavailable. Thus, this workstation must reroute messages to itself. This
is impossible.
System action: No rerouting is performed for the workstation indicated in the message. This may affect the
workload to be scheduled for this workstation.
User response: Use the TME 10 OPC dialog to check the alternate workstation names starting with this workstation.
Correct any workstation specifications that are incorrect.
To make the operations scheduled to start on this workstation eligible for TME 10 OPC scheduling, you must perform
manual actions. If no actions are taken, the operations on this workstation remain in RE status until a workstation
available event is received by the TME 10 OPC controller.
292 TME 10 OPC Messages and Codes