EQQW056I EQQW063E
EQQW056I

JOBNAME JOBNUM

HAS NO HELD SYSOUT IN CLASS
CLASS
Explanation: The CATMCLAS keyword specifies the SYSOUT class

CLASS

, but job
JOBNAME
with job ID
JOBNUM
created nonheld output in this class.
System action: The job is tracked as normal, but the joblog cannot be sent to the controller.
Problem determination: If the joblog output for the job is a held SYSOUT class, ensure the most current
EQQSSCMC lmod is active (see the SSCMNAME parameter).
System programmer response: Ensure that the CATMCLAS keyword specifies only held SYSOUT classes.
EQQW060E SUBMIT/RELEASE SKIP LIMIT DATE OR TIME

SKIPLIM

IS NOT VALID
Explanation: Initialization of the event writer failed because an operand of the SKIPDATE or SKIPTIME keyword in
the EWTROPTS statement was incorrectly specified.
System action: The event writer processing is terminated.
Problem determination: None.
System programmer response: Correct the operand in the EWTROPTS statement and then restart the event writer.
EQQW061W THE EVENT FILTERING EXIT LOAD MODULE,
MODULE
, COULD NOT BE LOADED
Explanation: The event writer could not locate the event filtering exit load module, EQQUX004.
System action: The event filtering exit will not be used by the event writer.
Problem determination: None.
System programmer response: If the event filtering exit is meant to be used, make sure that the EQQUX004 load
module is present in a library that can be reached by TME 10 OPC. Correct all errors and, if necessary, restart the
event writer.
EQQW062E EVENT WRITER INITIALIZATION FAILED
Explanation: The event writer could not acquire all resources required for normal operation. The most likely cause
of this error is that the event dataset or a submit/release dataset could not be opened. It is also possible that there
was an error in the EWTROPTS statement.
System action: The event writer processing is terminated. Message EQQZ045W is issued.
Problem determination: Review earlier messages in the TME 10 OPC message log to determine the exact reason
for this message.
System programmer response: Correct all errors and then restart the event writer.
EQQW063E THE JOB COMPLETION CHECKER WAS UNABLE TO BUILD THE GENERAL MESSAGE TABLE
Explanation: An error occurred while processing the JCC general message table. The general message table is
defined by member EQQGJCCT in the library defined by the EQQJCLIB DD statement.
System action: JCC initialization fails.
Problem determination: Review earlier messages in the TME 10 OPC message log to determine the exact reason
for this message.
System programmer response: Correct all errors and then restart the JCC.
Chapter 30. EQQWnnn Messages 305