EQQRM09E EQQRM16I
EQQRM09E RODM SUBTASK QUEUE POINTERS ARE DESTROYED, RODQ IS LOST
Explanation: The RODM subtask abended while processing elements on APPQ because the queue chaining is
invalid.
System action: MVS recovery/termination is requested to generate a dump. The RODM subtask restarts, and
resumes normal processing.
Problem determination: Review the TME 10 OPC message log dataset (EQQMLOG), the diagnostic dataset
(EQQDUMP), and the system dump dataset to determine the cause of the problem.
System programmer response: Save the EQQMLOG, EQQDUMP, and system dump datasets and contact your
IBM representative.
EQQRM11E RODM INTERFACE MODULE EKGUAPI COULD NOT BE LOADED
Explanation: A RODM interface module was not found in the library search path.
System action: TME 10 OPC continues, but the RODM functions as requested by RODMOPTS keywords referring
to this destination are disabled.
System programmer response: Make sure that the RODM interface modules are accessible either via the
LINKLST, or in the STEPLIB concatenation, and restart TME 10 OPC
EQQRM12W OPC RESOURCE UNKNOWN
NAME
Explanation: A RODMOPTS statement specifies a resource unknown to TME 10 OPC.
System action: This RODMOPTS statement is ignored. Processing continues. The status will be set to Inactive.
System programmer response: Specify a valid resource name, or add the resource to TME 10 OPC.
EQQRM13E OPC RESOURCE FIELD UNKNOWN
NAME
Explanation: A RODMOPTS statement specifies a resource field unknown to TME 10 OPC.
System action: RODM subtask initialization fails and the controller is shutdown.
System programmer response: Specify a valid resource field name and restart the controller.
EQQRM14W RODM OBJECT UNKNOWN
NAME
Explanation: A RODMOPTS statement specifies a RODM object unknown to TME 10 OPC.
System action: The OPCRESOURCE/OPCFIELD specified on the RODMOPTS statement referring to this RODM
OBJECT will be set to Inactive and processing continues. New subscription attempts will be performed every 5
minutes.
System programmer response: Specify a valid object name, or add the object to the RODM subsystem.
EQQRM15W RODM OBJECT FIELD UNKNOWN
NAME
Explanation: A RODMOPTS statement specifies a RODM field unknown to TME 10 OPC.
System action: The OPCRESOURCE/OPCFIELD specified on the RODMOPTS statement referring to this RODM
FIELD will be set to Inactive and processing continues.
System programmer response: Specify a valid RODM field name or add the field to the object in the RODM
subsystem.
EQQRM16I CONNECTION ESTABLISHED TO RODM SUBSYSTEM:
NAME
Explanation: TME 10 OPC has connected to a RODM subsystem.
System action: Processing continues.
User response: None.
244 TME 10 OPC Messages and Codes