EQQX265E EQQX268W
EQQX265E ATTEMPT TO READ A RECORD FAILED, REASON CODE
XSSRS
Explanation: The attempt to read a record failed. Reason code
XSSRS
provides debugging information for IBM
personnel.
System action: The request is rejected.
User response: Contact your system programmer.
System programmer response: Review the TME 10 OPC message log and look for I/O error messages issued at
the time of the request. Correct all errors and then restart the TME 10 OPC subsystem. If the error persists, collect
information in the form of the sequence of actions leading to the error, and if possible, the data it may be dependent
on. Then contact your IBM representative.
EQQX266E A JOBLIB OR PROCLIB RECORD READ FAILED, REASON CODE
XSSRS
Explanation: Reason code
XSSRS
gives the reason for the failure to read a record. The code issued depends on
the type of request.
The reason codes and their meanings are:
1The TME 10 OPC JCL library dataset (EQQJBLIB) could not be opened. Message EQQW500E in the TME 10
OPC message log, when issued at the time of TME 10 OPC start, further explains the reason for the failure.
2The TME 10 OPC JCL library dataset (EQQJBLIB) contains records with invalid length. Message EQQW501E in
the TME 10 OPC message log, when issued at the time of TME 10 OPC start, further explains the reason for the
failure.
3The joblib I/O exit, EQQUX002, was not loaded. Message EQQW521E in the TME 10 OPC message log, when
issued at the time of TME 10 OPC start, further explains the reason for the failure.
4The joblib I/O exit, EQQUX002, returned return code 241, which indicates that an I/O error has occurred in the exit
routine. Message EQQW520E in the TME 10 OPC message log further explains the reason for the I/O error.
5The joblib I/O exit, EQQUX002, returned return code 242, which indicates that it could not open one of its input
datasets. Message EQQW516E in the TME 10 OPC message log further explains the reason for the I/O error.
6The joblib I/O exit, EQQUX002, returned an invalid return code.
System action: An empty JCL member is presented.
User response: You may proceed by editing the empty JCL member. Then you should notify your system
programmer about the error.
System programmer response: To determine the cause of the error, use the reason code and the corresponding
message (if any) in the TME 10 OPC message log. Correct all errors and then restart the TME 10 OPC subsystem.
If the error persists, collect information in the form of the sequence of actions leading to the error, and if possible, the
data it may be dependent on. Then contact your IBM representative.
EQQX267W ACCESS REJECTED, DATA SET USED BY ANOTHER OPC/ESA FUNCTION
Explanation: The record could not be read because the dataset was held for update by another TME 10 OPC
function.
System action: The request is rejected.
User response: Try again later.
EQQX268W UPDATE REJECTED, DATA SET USED BY ANOTHER OPC/ESA FUNCTION
Explanation: The record update could not be carried out because the dataset was held for update by another
TME 10 OPC function.
System action: The request is rejected.
User response: Try again later.
Chapter 31. EQQXnnn Messages 341